Impact of aortic annulus size on valve hemodynamics and clinical outcomes after transcatheter and surgical aortic valve replacement: insights from the PARTNER Trial.

نویسندگان

  • Josep Rodés-Cabau
  • Philippe Pibarot
  • Rakesh M Suri
  • Susheel Kodali
  • Vinod H Thourani
  • Wilson Y Szeto
  • Lars G Svensson
  • Eric Dumont
  • Ke Xu
  • Rebecca T Hahn
  • Martin B Leon
چکیده

BACKGROUND The objective was to evaluate the effects of aortic annulus size on valve hemodynamics and clinical outcomes in those patients included in the Placement of Aortic Transcatheter Valves (PARTNER) randomized controlled trial cohort A and the nonrandomized continued access cohort. METHODS AND RESULTS Patients included the randomized controlled trial (n=574) and nonrandomized continued access (n=1358) cohorts were divided in tertiles according to aortic annulus diameter (small aortic annulus tertile, medium aortic annulus tertile, and large aortic annulus tertile [LAA], respectively) as measured by transthoracic echocardiography. Severe prosthesis-patient mismatch was defined as an effective aortic orifice area of <0.65 cm(2)/m(2). In the randomized controlled trial cohort, patients in the small aortic annulus tertile who underwent transcatheter aortic valve replacement had a lower incidence of severe prosthesis-patient mismatch (19.7% versus 37.5%; P=0.03) and only a trend toward a higher incidence of moderate-to-severe paravalvular leaks compared with surgical aortic valve replacement (5.7% versus 0%; P=0.06). In the LAA tertile, there were no differences in the rate of prosthesis-patient mismatch between groups, and a significant increase in moderate-to-severe paravalvular leaks was associated with transcatheter aortic valve replacement (9% versus 0%; P=0.01). There were no differences in mortality between transcatheter aortic valve replacement and surgical aortic valve replacement. In the nonrandomized continued access cohort, there were no differences in prosthesis-patient mismatch between the small aortic annulus and LAA tertiles, but a higher rate of moderate-to-severe paravalvular leaks was observed in the LAA tertile (5.9% versus 11.5%; P=0.009). Patients in the LAA tertile had a higher mortality rate at 1-year follow-up (P=0.02), and differences persisted in multivariable analysis (P=0.048 for LAA versus medium aortic annulus tertile, P=0.035 for LAA versus small aortic annulus tertile). CONCLUSIONS Aortic annulus size had a major impact on valve hemodynamics and clinical outcomes after transcatheter aortic valve replacement and surgical aortic valve replacement. This study highlights the importance of considering aortic annulus size in the evaluation of high-risk patients who are candidates for aortic valve replacement. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT00530894.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Comparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery

Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...

متن کامل

Implications of Contemporary Clinical Trials The Placement of Aortic Transcatheter Valve (PARTNER) Trial Clinical Trialist Perspective

For several decades, surgical aortic valve replacement (sAVR) has been considered the therapeutic gold standard for the treatment of severe aortic stenosis (AS). Severe AS is a progressive disease with a long latency period, and despite significant strides in medical therapy for numerous other forms of cardiovascular disease, little progress has been made in medical therapy for AS. The mechanic...

متن کامل

Transcatheter aortic valve implantation in patients with severe aortic stenosis and small aortic annulus.

OBJECTIVES Valve hemodynamics and clinical outcomes among patients with a small aortic annulus who underwent transcatheter aortic valve implantation (TAVI) were examined. BACKGROUND The presence of a small aortic annulus may complicate the surgical management of patients with severe aortic stenosis (AS). TAVI is an alternative to aortic valve replacement (AVR) in high-risk patients, but few d...

متن کامل

Atrial Fibrillation Is Associated With Increased Mortality in Patients Undergoing Transcatheter Aortic Valve Replacement: Insights From the Placement of Aortic Transcatheter Valve (PARTNER) Trial.

BACKGROUND This study sought to evaluate the impact of atrial fibrillation (AF) on clinical outcomes in patients undergoing transcatheter aortic valve replacement. METHODS AND RESULTS Data were evaluated in 1879 patients with baseline and discharge ECGs who underwent transcatheter aortic valve replacement in the Placement of AoRTic TraNscathetER Valve (PARTNER) trial. A total of 1262 patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 2014