Four-Rod Stabilization of Severely Destabilized Lumbar Spine Caused by Metastatic Tumor
نویسندگان
چکیده
We report a case of a 67-year-old female with severely destabilized lumbar spine caused by metastatic malignant tumor. The primary lesion was a thyroid follicular adenocarcinoma. Complete destruction of the L3, L4, and L5 vertebrae had resulted in severe instability, which left the patient with severe back pain and bed-ridden. Since the vertebrae were so severely damaged at 3 levels, 4 rods were used to stabilize the spine. Following stabilization, the pain was alleviated and the patient's quality of life improved. We introduce here the 4-rod technique to stabilize the spine over 3 vertebral levels following severe destruction by metastatic tumor.
منابع مشابه
In Vitro Comparison of Dynesys, PEEK, and Titanium Constructs in the Lumbar Spine
Introduction. Pedicle based posterior dynamic stabilization systems aim to stabilize the pathologic spine while also allowing sufficient motion to mitigate adjacent level effects. Two flexible constructs that have been proposed to act in such a manner, the Dynesys Dynamic Stabilization System and PEEK rod, have yet to be directly compared in vitro to a rigid Titanium rod. Methods. Human lumbar ...
متن کاملSpinal-pelvic fixation in patients with lumbosacral neoplasms.
OBJECT Primary and metastatic neoplasms of the lumbosacral junction frequently pose a complex problem for the surgical management and stabilization of the spine because of the anatomical and biomechanical factors of this transition zone between spine and pelvis. The authors have used a modification of the Galveston technique, originally described by Allen and Ferguson in the treatment of scolio...
متن کاملEasily misdiagnosed delayed metastatic intraspinal extradural melanoma of the lumbar spine: A case report and review of the literature
Metastatic melanoma of the spine usually occurs as vertebral metastatic melanoma or intramedullary spinal cord metastatic melanoma. The present study reports a case of easily misdiagnosed delayed metastatic intraspinal extradural melanoma of the lumbar spine. A 67-year-old female patient presented with lower back pain accompanied by progressive intermittent claudication. Magnetic resonance imag...
متن کاملPerpendicular Iliac Screw Placement for Reinforcement of Spinopelvic Stabilization.
Iliac fixation is indicated to provide spinopelvic stabilization in select cases of long segment thoracolumbar spine fusion, spinal osteotomy/realignment, trauma, and instability caused by tumor or infection. Traditional iliac fixation with iliac screws or S2 alar/iliac (S2AI) screws may provide inadequate fixation in select clinical scenarios, such as severely compromised bone quality or spino...
متن کاملComparison of the Rigid Rod System with Modular Plate with the Finite Element Analysis in Short-Segment Posterior Stabilization in the Lower Lumbar Region.
AIM Many studies are available in the literature on posterior spinal instrumentation, though the use of a rod and a plate is still controversial in the literature. In this study, a finite element analysis of the strength and superiority of modular rigid plate and rod systems, which are used in the lower lumbar region, in comparison with each other was used. MATERIAL AND METHODS A Ti6Al4V (Gra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013