Multicenter Evaluation of the Accelerate PhenoTest BC Kit for Rapid Identification and Phenotypic Antimicrobial Susceptibility Testing Using Morphokinetic Cellular Analysis

نویسندگان

  • Preeti Pancholi
  • Karen C Carroll
  • Blake W Buchan
  • Raymond C Chan
  • Neelam Dhiman
  • Bradley Ford
  • Paul A Granato
  • Amanda T Harrington
  • Diana R Hernandez
  • Romney M Humphries
  • Matthew R Jindra
  • Nathan A Ledeboer
  • Shelley A Miller
  • A Brian Mochon
  • Margie A Morgan
  • Robin Patel
  • Paul C Schreckenberger
  • Paul D Stamper
  • Patricia J Simner
  • Nancy E Tucci
  • Cynthia Zimmerman
  • Donna M Wolk
چکیده

We describe results from a multicenter study evaluating the Accelerate Pheno system, a first of its kind diagnostic system that rapidly identifies common bloodstream pathogens from positive blood cultures within 90 min and determines bacterial phenotypic antimicrobial susceptibility testing (AST) results within ∼7 h. A combination of fresh clinical and seeded blood cultures were tested, and results from the Accelerate Pheno system were compared to Vitek 2 results for identification (ID) and broth microdilution or disk diffusion for AST. The Accelerate Pheno system accurately identified 14 common bacterial pathogens and two Candida spp. with sensitivities ranging from 94.6 to 100%. Of fresh positive blood cultures, 89% received a monomicrobial call with a positive predictive value of 97.3%. Six common Gram-positive cocci were evaluated for ID. Five were tested against eight antibiotics, two resistance phenotypes (methicillin-resistant Staphylococcus aureus and Staphylococcus spp. [MRSA/MRS]), and inducible clindamycin resistance (MLSb). From the 4,142 AST results, the overall essential agreement (EA) and categorical agreement (CA) were 97.6% and 97.9%, respectively. Overall very major error (VME), major error (ME), and minor error (mE) rates were 1.0%, 0.7%, and 1.3%, respectively. Eight species of Gram-negative rods were evaluated against 15 antibiotics. From the 6,331 AST results, overall EA and CA were 95.4% and 94.3%, respectively. Overall VME, ME, and mE rates were 0.5%, 0.9%, and 4.8%, respectively. The Accelerate Pheno system has the unique ability to identify and provide phenotypic MIC and categorical AST results in a few hours directly from positive blood culture bottles and support accurate antimicrobial adjustment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Impact of MALDI-TOF MS Identification and Rapid Susceptibility Testing on Adequate Antimicrobial Treatment in Sepsis with Positive Blood Cultures

Shortening the turn-around time (TAT) of positive blood culture (BC) identification (ID) and susceptibility results is essential to optimize antimicrobial treatment in patients with sepsis. We aimed to evaluate the impact on antimicrobial prescription of a modified workflow of positive BCs providing ID and partial susceptibility results for Enterobacteriaceae (EB), Pseudomonas aeruginosa and St...

متن کامل

Molecular Identification and Conventional Susceptibility Testing of Iranian Clinical Mycobacterium fortuitum Isolates

Objective(s) Rapidly growing mycobacteria (RGM) are capable of producing diseases in humans. Since mycobacteria vary in their susceptibility, precise identification is critical for adoption of correct drug therapy. The main aim of this study was molecular identification and evaluation of antimicrobial susceptibility pattern of Iranian clinically isolated Myocbacterium fortuitum. Materials and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 56  شماره 

صفحات  -

تاریخ انتشار 2018