Real Time Processing and Transferring ECG Signal by a Mobile Phone
نویسندگان
چکیده
The real-time ECG signal processing system based on mobile phones is very effective in identifying continuous ambulatory patients. It could monitor cardiovascular patients in their daily life and warns them in case of cardiac arrhythmia. An ECG signal of a patient is processed by a mobile phone with this proposed algorithm. An IIR low-pass filter is used to remove the noise and it has the 55 Hz cutoff frequency and order 3. The obtained SNR showed a desirable noise removal and it helps physicians in their diagnosis. In this paper, Hilbert transform was used and the R peaks are important component to differ normal beats from abnormal ones. The results of sensitivity and positive predictivity of algorithm are 96.97% and 95.63% respectively. If an arrhythmia occurred, 4 seconds of this signal is displayed on the mobile phone then it will be sent to a remote medical center by TCP/IP protocol.
منابع مشابه
Development of a Mobile Phone Based e-Health Monitoring Application
The use of Electrocardiogram (ECG) system is important in primary diagnosis and survival analysis of the heart diseases. Growing portable mobile technologies have provided possibilities for medical monitoring for human vital signs and allow patient move around freely. In this paper, a mobile health monitoring application program is described. This system consists of the following sub-systems: r...
متن کاملDetection and Classification of Epileptic Seizure using RBF Neural Network
The rapid growth of the medical technologies and constant renewal of medical facilities, electrocardiography (ECG) provides an effective and easy to use means for arrhythmia classification and heart rate variability (HRV) analysis. Most of the existing ECG device has the disadvantage of poor local signal processing ability. After thorough investigation, Android platform is adopted to develop an...
متن کاملReal Time Analysis and Diagnosis of ECG Signal for Tachycardia Condition
With heart diseases, and associated complications, being one of the major causes of death around the world, and in spite of decreased mortality rate, detection of irregularities in the rhythms of the heart is a growing field in medical research. Extended patient monitoring during normal activity has become increasingly important as a standard preventive cardiological procedure for detection of ...
متن کاملCan the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?
Background: People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors.Methods: Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed ...
متن کاملA QRS Detection and R Point Recognition Method for Wearable Single-Lead ECG Devices
In the new-generation wearable Electrocardiogram (ECG) system, signal processing with low power consumption is required to transmit data when detecting dangerous rhythms and to record signals when detecting abnormal rhythms. The QRS complex is a combination of three of the graphic deflection seen on a typical ECG. This study proposes a real-time QRS detection and R point recognition method with...
متن کامل