An Automated Multicommuted Flow Analysis Procedure for Photometric Determination of Reducing Sugars in Wine Employing a Directly Heated Flow‐Batch Device

نویسنده

  • Marcos A. S. Brasil
چکیده

This work presents an automated analytical procedure for the photometric determination of reducing sugars in wines. The procedure is based on the reaction of reducing sugars with potassium hexacyanoferrate(III) in an alkaline medium, and was implemented employing a multicommuted flow analysis (MCFA) approach. Sample heating to promote the reaction was accomplished using a flow-batch device, which was heated to 50 °C without the use of a fluid for heat exchange. The ability of the MCFA approach to handle small solution volumes was exploited in order to develop an analytical procedure that meets green analytical chemistry guidelines. After optimizing the operational variables, the analytical procedure afforded a linear response ranging from 0.75 to 6.00% (m/v) fructose (R = 0.999), a limit of detection of 0.14% fructose (n = 11), a 3.5% relative standard deviation, reagent consumption and waste generation of 112 mg and 2.2 mL per determination, respectively, and an analytical throughput of 75 determinations per hour.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Instrumentation and Automated Photometric Titration Procedure for Total Acidity Determination in Red Wine Employing a Multicommuted Flow System

An automated procedure for photometric titration of red wine and associated instrumentation is described. The procedure was based on the flow-batch approach implemented employing multicommutation. The photometric detection was carried out using a homemade LED-based photometer. The mixing device, LED, and photodetector were attached to the titration chamber in order to form a compact and small-s...

متن کامل

An Environmental Friendly Procedure for Photometric Determination of Hypochlorite in Tap Water Employing a Miniaturized Multicommuted Flow Analysis Setup

A photometric procedure for the determination of ClO(-) in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4',4''-methylidynetris (N,N-dimethylaniline), C(25)H(31)N(3)) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assem...

متن کامل

A Highly Sensitive Multicommuted Flow Analysis Procedure for Photometric Determination of Molybdenum in Plant Materials without a Solvent Extraction Step

A highly sensitive analytical procedure for photometric determination of molybdenum in plant materials was developed and validated. This procedure is based on the reaction of Mo(V) with thiocyanate ions (SCN-) in acidic medium to form a compound that can be monitored at 474 nm and was implemented employing a multicommuted flow analysis setup. Photometric detection was performed using an LED-bas...

متن کامل

A Full Automatic Device for Sampling Small Solution Volumes in Photometric Titration Procedure Based on Multicommuted Flow System

In this work, an automatic device to deliver titrant solution into a titration chamber with the ability to determine the dispensed volume of solution, with good precision independent of both elapsed time and flow rate, is proposed. A glass tube maintained at the vertical position was employed as a container for the titrant solution. Electronic devices were coupled to the glass tube in order to ...

متن کامل

Determination of polyphenols in wines by reaction with 4-aminoantipyrine and photometric flow-injection analysis.

A new flow-injection analytical procedure is proposed for the determination of the total amount of polyphenols in wines; the method is based on the formation of a colored complex between 4-aminoantipyrine and phenols, in the presence of an oxidizing reagent. The oxidizing agents hexacyanoferrate(III), peroxodisulfate, and tetroxoiodate(VII) were tested. Batch trials were first performed to sele...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017