Non-expert use of the cerebral function monitor for neonatal seizure detection.

نویسندگان

  • J M Rennie
  • G Chorley
  • G B Boylan
  • R Pressler
  • Y Nguyen
  • R Hooper
چکیده

BACKGROUND The cerebral function monitor (CFM) is widely used to detect neonatal seizures, but there are very few studies comparing it with simultaneous electroencephalography (EEG). OBJECTIVE To determine the accuracy of non-expert use of the CFM and to assess interobserver agreement of CFM seizure detection. PATIENTS Babies admitted to the neonatal intensive care unit at King's College Hospital who were at high risk of seizure and had video-EEG monitoring. METHODS Video-EEG was used to detect seizures. Each baby had CFM recordings at speeds of 6, 15, and 30 cm/h during the EEG. Four neonatologists, trained in CFM seizure recognition, independently rated one hour CFM samples at three speeds from each baby. Interobserver agreement was quantified using Cohen's kappa. RESULTS CFM traces from 19 babies with EEG seizures and 21 babies without EEG seizures were analysed. Overall non-expert interpretation of the CFM performed poorly as a seizure detector compared with simultaneous EEG (sensitivities 38% at 6 cm/h; 54% at 15 cm/h; 55% at 30 cm/h). Although babies with seizures were more likely to be correctly classified at higher speeds (p = 0.02), babies without seizures were also more likely to be misclassified (p < 0.001). Agreement between observers was not good at any speed (kappa values from 0.01 to 0.39). The observers usually detected generalised seizures but often missed seizures that were focal, low amplitude, or lasted less than one minute. CONCLUSION Approximately half of all neonatal seizures may be missed using CFM alone. Neonatal seizures need to be diagnosed, characterised, and quantified first using EEG. The CFM may then be useful for long term monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-depth performance analysis of an EEG based neonatal seizure detection algorithm

OBJECTIVE To describe a novel neurophysiology based performance analysis of automated seizure detection algorithms for neonatal EEG to characterize features of detected and non-detected seizures and causes of false detections to identify areas for algorithmic improvement. METHODS EEGs of 20 term neonates were recorded (10 seizure, 10 non-seizure). Seizures were annotated by an expert and char...

متن کامل

Brain monitoring in neonates.

Continuous EEG monitoring with amplitude-integrated electroencephalography (aEEG) has become a part of the routine neurological care in the neonatal unit, especially in full-term infants with hypoxia-ischemia and in infants suspected of seizures. Its prognostic value after birth asphyxia is well established and seizure detection has improved with the new digital aEEG devices with access to the ...

متن کامل

صرع در کودکان مبتلا به فلج مغزی

In a cross-sectional study over a period of two years (Dec.2001- Dec.2003), 68 children with cerebral palsy(CP) and seizure aged 1-12 years were evaluated prospectively in Hazrat Rasoul Hospital. A control group of 60 children with seizure but no cerebral palsy at the same age group was also studied. The objective of the study was to find out the relationship between cerebral palsy ...

متن کامل

An evaluation of automated neonatal seizure detection methods.

OBJECTIVE To evaluate 3 published automated algorithms for detecting seizures in neonatal EEG. METHODS One-minute, artifact-free EEG segments consisting of either EEG seizure activity or non-seizure EEG activity were extracted from EEG recordings of 13 neonates. Three published neonatal seizure detection algorithms were tested on each EEG recording. In an attempt to obtain improved detection ...

متن کامل

The Experimental Study of Increased ICP on Cerebral Hemorrhage Rabbits with Magnetic Induction Phase Shift Method

Introduction Measuring magnetic induction phase shift (MIPS) changes as a function of cerebral hemorrhage volume has the potential for being a simple method for primary and non-contact detection of the occurrence and progress of cerebral hemorrhage. Our previous MIPS study showed that the intracranial pressure (ICP) was used as a contrast index and found the primary correlation between MIPS and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 89 1  شماره 

صفحات  -

تاریخ انتشار 2004