A scheme for multisource interior tomography.
نویسندگان
چکیده
Currently, x-ray computed tomography (CT) requires source scanning so that projections can be collected from various orientations for image reconstruction. Limited by the scanning time, the temporal resolution of CT is often inadequate when rapid dynamics is involved in an object to be reconstructed. To meet this challenge, here the authors propose a scheme of multisource interior tomography for ultrafast imaging that reconstructs a relatively small region of interest (ROI). Specifically, such a ROI is irradiated in parallel with narrow x-ray beams defined by many source-detector pairs for data acquisition. This ROI can be then reconstructed using the interior tomography approach. To demonstrate the merits of this approach, the authors report interior reconstruction from in vivo lung CT data at a much reduced radiation dose, which is roughly proportional to the ROI size. The results suggest a scheme for ultrafast tomography (such as with a limited number of sources and in a scanning mode) to shorten data acquisition time and to suppress motion blurring.
منابع مشابه
Grid-price-dependent Energy Management of a Building Supplied by a Multisource System Integrated with Hydrogen
This paper studies power management in a grid-tied hybrid energy system consisting of photovoltaic array, wind turbine, fuel cell, electrolyzer, hydrogen storage tank and a combinational heating system to supply the thermal and electrical demand of a building. Moreover, the hybrid system is capable of exchanging power with local grid. Thus, variable daily buying and selling tariffs are also tak...
متن کاملPerformance Improvement of Direct Torque Controlled Interior Permanent Magnet Synchronous Motor Drives Using Artificial Intelligence
The main theme of this paper is to present novel controller, which is a genetic based fuzzy Logic controller, for interior permanent magnet synchronous motor drives with direct torque control. A radial basis function network has been used for online tuning of the genetic based fuzzy logic controller. Initially different operating conditions are obtained based on motor dynamics incorporating...
متن کاملImage reconstruction from limited angle projections
A multisource x-ray interior imaging system with limited angle scanning is investigated to study the possibility of building an ultrafast microCT for dynamic small animal imaging, and two methods are employed to perform interior reconstruction from a limited number of projections collected by the multisource interior x-ray system. The first is total variation minimization with the steepest desc...
متن کاملA multi-phase level set framework for source reconstruction in bioluminescence tomography
We propose a novel multi-phase level set algorithm for solving the inverse problem of bioluminescence tomography. The distribution of unknown interior source is considered as piecewise constant and represented by using multiple level set functions. The localization of interior bioluminescence source is implemented by tracing the evolution of level set function. An alternate search scheme is inc...
متن کاملEvaluation of the Efficacy of Standardized Uptake Value (SUV)-shape Scheme for Thyroid Volume Determination in Graves’ Disease: A Comparison with Ultrasonography
Objective(s): In this study, we aimed to evaluate the efficacy of thyroid volume measurement using 99mTc pertechnetate single-photon emission computed tomography (SPECT) images, acquired by the standardized uptake value (SUV)-shape scheme designed by our expert team.Methods: A total of 18 consecutive patients with Graves’ disease (GD) were subjected to both ultrasonographic and 99mTc pertechnet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 36 8 شماره
صفحات -
تاریخ انتشار 2009