Glucose biosensing using glassy carbon electrode modified with polyhydroxy-C60, glucose oxidase and ionic-liquid.

نویسندگان

  • Tian Yang
  • Xiao-Lu Yang
  • Yu-Shuai Zhang
  • BaoLin Xiao
  • Jun Hong
چکیده

Direct electrochemistry of glucose oxidase (GOD) was achieved when an ionic liquid/GOD-Polyhydroxy-C60 functional membrane was confined on a glassy carbon electrode (GCE). The cyclic voltammograms (CVs) of the modified GCE showed a pair of redox peaks with a formal potential (E°') of - 329 ± 2 mV. The heterogeneous electron transfer constant (k(s)) was 1.43 s-1. The modified GCE response to glucose was linear in the range from 0.02 to 2.0 mM. The detection limit was 1 μM. The apparent Michaelis-Menten constant (K(m)(app)) was 1.45 mM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Covalent Modification of Glassy Carbon Electrode with an Imidazolium based Methoxysilyl Ionic Liquid Nanoparticles: Application in Determination of Redox System

Glassy carbon (GC) is the most commonly used carbon-based electrode in the analytical laboratory. Because of the high background current and low electrode response, modification of this electrode can be done by various materials and techniques. An ionic liquid (IL), 1-methyl-3-(3-trimethoxysilyl propyl) imidazoliumbis (trifluoromethylsulfonyl) imide, was covalently cross linked onto the GC surf...

متن کامل

Electrochemical Oxidation of Flavonoids and Interaction with DNA on the Surface of Supramolecular Ionic Liquid Grafted on Graphene Modified Glassy Carbon Electrode

The study of the interaction between DNA and small molecules such as drugs is one of the current general interest and importance. In this paper, the electrochemical investigation of the interaction between some flavonoids such as rutin, quercetin, and hesperidin with dsDNA on the surface of Supramolecular Ionic Liquid grafted on the Graphene Oxide Modified Glassy Carbon Electrode (</s...

متن کامل

Double Biocatalysis Signal Amplification Glucose Biosensor Based on Porous Graphene

Controllable preparation of nanopores to promote the performance of electrochemical biosensing interfaces has become one of the researching frontiers in biosensing. A double biocatalysis signal amplification of glucose biosensor for the study of electrochemical behaviors of glucose oxidase (GOx) was proposed by using horseradish peroxidase biosynthesized porous graphene (PGR) as the platform fo...

متن کامل

Electroanalytical sensing of Asulam based on nanocomposite modified glassy carbon electrode

In this study a facile approach to employ Copper nanoparticle (CuNPs) and multi-walled carbon nanotubes (MWCNT) as the nanomaterial for selective detection of asulam have been investigated. This work reports the electrocatalytic oxidation of asulam on glassy carbon electrodes (GCE) modified with multi-walled carbon nanotubes (MWCNT), ionic liquids (IL), chitosan (Chit) and copper nanoparticles ...

متن کامل

Electrochemical glucose biosensing by pyranose oxidase immobilized in gold nanoparticle-polyaniline/AgCl/gelatin nanocomposite matrix

0308-8146/$ see front matter 2009 Elsevier Ltd. A doi:10.1016/j.foodchem.2009.05.087 * Corresponding author. Tel./fax: +90 232 3438624 E-mail address: [email protected] (S. Timur). A novel pyranose oxidase (PyOx) biosensor based on gold nanoparticles (AuNPs)–polyaniline(PANI)/AgCl/ gelatin nanocomposite has been developed for the glucose detection. PyOx was immobilized on the surface of glass...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bio-medical materials and engineering

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2014