Quantitative assessment of dacryoscintigraphic images in the evaluation of epiphora.
نویسندگان
چکیده
BACKGROUND At the present time, only visual analysis is implemented on dacryoscintigraphic images and quantitative assessments are not routinely obtained. The authors have designed a novel, simple, quantitative method for the diagnosis of sac and post-sac obstructions based on the dacryoscintigraphic images. METHOD Fifty-nine patients with severe unilateral epiphora were included and the contralateral asymptomatic eyes were used as controls. After ocular instillation of 0.1 cc isotonic saline containing 4 MBq 99mTcO4, dynamic images were obtained for 20 minutes. Visual interpretation was done by two blinded specialists in nuclear medicine. A Time-Activity Curve (TAC) was generated for each eye and its pattern was divided to plateau type, shallow-down sloping and deep-down sloping. The excretion ratio (expressed as the percentage of drained activity) in the 2nd, 3rd, 5th, 7th, 10th, 15th and 20th minute of the study was calculated based on the following formula: (the total count in the region of interest (ROI) in the 1st minute - the total ROI count in the 2nd, 3rd, 5th, 7th, 10th, 15th or 20th minute/the total ROI count in the 1st minute) x 100. The results of the quantitative analysis were compared with the clinical symptoms, visual analysis and TAC pattern. RESULTS At the optimal cut-off points for the 2nd, 3rd, 5th and 7th minute, the sensitivity of the prediction of obstruction was 76%, 72%, 71% and 69%, respectively. The correlation between visual interpretation and the TAC pattern was statistically significant. CONCLUSION The quantitative evaluation of dacryoscintigraphic images would contribute greatly to achieving an easier and more objective interpretation of the scintigraphic results and also provides a reliable tool for inter-individual comparison and the follow-up of patients. As it is the first time that this innovative method has been examined clinically, it will be necessary to investigate its clinical utility in a larger series of patients.
منابع مشابه
Quantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation
Background: Accurate brain tissue segmentation from magnetic resonance (MR) images is an important step in analysis of cerebral images. There are software packages which are used for brain segmentation. These packages usually contain a set of skull stripping, intensity non-uniformity (bias) correction and segmentation routines. Thus, assessment of the quality of the segmented gray matter (GM), ...
متن کاملEvaluation of lacrimal drainage system by radionuclide dacryoscintigraphy in patients with epiphora
Introduction: This study was done to determine the site of obstruction in lacrimal drainage system in Asian patients suffering from epiphora and to determine the transit time taken for the tracer material to reach the lacrimal sac and the nasal cavity. Methods:Dacryoscintigraphy was performed using radionuclide technetium-99m pertechnetate (99m...
متن کاملA New Approach for Quantitative Evaluation of Reconstruction Algorithms in SPECT
ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance. In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...
متن کاملShearlet-Based Adaptive Noise Reduction in CT Images
The noise in reconstructed slices of X-ray Computed Tomography (CT) is of unknown distribution, non-stationary, oriented and difficult to distinguish from main structural information. This requires the development of special post-processing methods based on the local statistical evaluation of the noise component. This paper presents an adaptive method of reducing noise in CT images employing th...
متن کاملEvaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orbit
دوره 26 4 شماره
صفحات -
تاریخ انتشار 2007