Determination of enzyme activity in biological fluids by means of electrochemical oxidation of NADH at a modified glassy carbon electrode.

نویسندگان

  • L Bartalits
  • G Nagy
  • E Pungor
چکیده

This amperometric technique for the determination of enzyme activity is based on detecting a decrease in the concentration of the NADH co-factor of the enzyme reaction. A glassy carbon electrode, modified by adsorption of Mg2+ and NADH, is used to measure the anodic peak current that corresponds to the oxidation of NADH. We found no significant difference between the enzyme activity of lactate dehydrogenase (E.C.1.1.1.27) preparations as measured by the above amperometric technique and by a spectrophotometric method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study and Electrochemical Determination of Tyrosine at Graphene Nanosheets Composite Film Modified Glassy Carbon Electrode

A graphene nanosheets (GNS) film coated glassy carbon electrode (GCE) was fabricated for sensitive determination of tyrosine (Tyr). The GNS-based sensor was characterized by scanning electron microscope and electrochemical impedance spectroscopy. The voltammetric techniques were employed to study electro-oxidation of Tyr. The results revealed that the modified electrode showed an electrocatalyt...

متن کامل

Selective Electrochemical Nanosensor based on Modified Carbon Paste Electrode for Determination of NADH in the presence of Uric Acid

The electrochemical properties of a modified carbon paste electrode with the synthesized compound of 2,2'-[1,7–heptanediylbis(nitrilomethylidene)]-bis(4-hydroxyphenol) (DHBH) and graphite nanoparticle (GN) were studied by cyclic voltammetry (CV), chronoamperometry and differential pulse voltammetry (DPV) methods. The proposed electrode shows excellent electrocatalytic activity towards the oxida...

متن کامل

Detection of Ascorbic Acid in Biological Samples by a New Modified Glassy Carbon Electrode

The present work describes the construction of a new modified electrode by casting the appropriate mixture of a metallocene, which has been introduced in the experimental part, as a mediator at the surface of glassy carbon (GC) electrode. The proposed modified GC electrode was used for the determination of ascorbic acid (AA) in phosphate buffer (PB) solution (pH = 4.0). When compared to bare GC...

متن کامل

Electrochemical Oxidation of Sulfamethazine on Multi-Walled Nanotube Film Coated Glassy Carbon Electrode

The electrochemical oxidation of sulfamethazine (SMZ) has been studied at a multi-walled carbon nanotubes modified glassy carbon electrode (MWCNT-GCE) by cyclic voltammetry. This modified electrode (MWCNT-GCE) exhibited excellent electrocatalytic behavior toward the oxidation of SMZ as evidenced by the enhancement of the oxidation peak current and the shift in the anodic potential to less posit...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 11  شماره 

صفحات  -

تاریخ انتشار 1984