Lung toxicity in radioiodine therapy of thyroid carcinoma: development of a dose-rate method and dosimetric implications of the 80-mCi rule.
نویسندگان
چکیده
UNLABELLED Based on an extensive dataset analyzed by Benua et al., a whole-body retention threshold of 2.96 GBq (80 mCi) at 48 h has been used to limit the radioactivity of (131)I administered to thyroid cancer patients with diffuse pulmonary metastases. In this work, the 80-mCi activity retention limit is used to derive lung-absorbed doses and dose rates. The resulting dose-rate-based limits make it possible to account for patient-specific differences in lung geometry. This is particularly important, for example, in pediatric patients exhibiting diffuse lung metastases. The approach also highlights the impact of altered radioiodine kinetics as seen with recombinant human thyroid-stimulating hormone. METHODS The dose-rate constraint (DRC) was defined as the absorbed dose rate to the lungs of the adult female reference phantom when 80 mCi of (131)I are in the body and 90% of this is uniformly distributed in the lungs. With this definition, the 80-mCi rule was generalized by calculating the activity required to yield a dose rate equal to DRC using lung-to-lung S factor values corresponding to different reference phantoms. RESULTS A DRC value of 43.6 cGy/h was obtained. Applying this DRC to the adult male phantom and to the phantom of a 15-y-old yields equivalent 48-h activity limits of 3.72 GBq (101 mCi) and 2.45 GBq (66.2 mCi), respectively. Depending on model parameters, the absorbed doses to lungs ranged from 57 to 112 Gy; the photon-only portion, which better reflects the dose to normal lung parenchyma, ranged from 4.9 to 55 Gy. CONCLUSION A dose-rate-based version of the 80-mCi rule is derived and used to demonstrate application of this rule to pediatric patients and to adult male patients. The implications of the 80-mCi rule are also examined. The assumption of uniform energy deposition in the lungs leads to substantially overestimated absorbed doses. Severe radiation-induced lung toxicity, expected at normal lung absorbed doses of 25-27 Gy, is avoided, probably because most of the local electron dose is delivered to tumor tissue instead of to normal lung parenchyma. The possibility of using a DRC to adjust treatment for different clinical situations is illustrated. The analysis suggests that a dosimetry-based approach will be particularly important in the treatment of patients with lung metastases when a recombinant human thyroid-stimulating hormone protocol is used.
منابع مشابه
Determination of organ doses in radioiodine therapy using medical internal radiation dosimetry (MIRD) method
Background: Radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. The scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (MIRD) method. At the end, the results of MIRD calculations were compared with thermoluminescent dosimeter (TLD...
متن کاملEffects of early liothyronine consumption after radioiodine therapy on accumulated dose and exposure rate in patients with thyroid carcinoma
Introduction: Patients administered with a therapeutic dose of 131I for thyroid cancer treatment are potential sources of unacceptably high radiation exposure to other individuals, particularly the patient's immediate family members. The aim of this study is to investigate effects of early liothyronine consumption after radio-iodine therapy on accumulated dose and e...
متن کاملمقایسه نتایج دو روش درمان با I¹³¹ با دوز ثابت 5 میلی کوری و دوز ثابت 10 میلی کوری در درمان بیماری گریوز، بیمارستان شریعتی، 80-1378
Radioiodine therapy is the safest, simplest, least expensive and most effective method for treatment of Graves' disease. Due to difficulties in previous methods for dose determination, fixed dose method of 1-131 is now considered the best practical method for 1-131 therapy in Graves' disease, but there is no consensus on the dose. We compared two routinely recommended fixed doses of 5 and 10 mC...
متن کاملLung dosimetry for radioiodine treatment planning in the case of diffuse lung metastases.
UNLABELLED The lungs are the most frequent sites of distant metastasis in differentiated thyroid carcinoma. Radioiodine treatment planning for these patients is usually performed following the Benua-Leeper method, which constrains the administered activity to 2.96 GBq (80 mCi) whole-body retention at 48 h after administration to prevent lung toxicity in the presence of iodine-avid lung metastas...
متن کاملDetermination of absorbed dose of organs (thyroid, sternum, cervical vertebra) in thyroid cancer patients following radioiodine therapy
Introduction: In patients with thyroid carcinoma, radiation absorbed doses of the thyroid and surrounding tissues is important to weigh risk and benefit considerations. In nuclear medicine, the accuracy of absorbed dose of internally distributed radionuclides is estimated by different methods such as MIRD and direct method using TLD. The aim of this study is using T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 47 12 شماره
صفحات -
تاریخ انتشار 2006