Air-assisted Descemet-stripping automated endothelial keratoplasty with posterior chamber iris-fixation of aphakic iris-claw intraocular lens.
نویسندگان
چکیده
We report a combination of surgical techniques during Descemet-stripping automated endoithelial keratoplasty and intraocular lens (IOL) exchange in patients with pseudophakic bullous keratopathy and angle-supported anterior chamber IOLs. During this procedure, the anterior chamber IOL is exchanged for a posterior chamber iris-claw IOL enclavated to the posterior iris; the anterior chamber is kept filled with air using an air-fluid exchange machine during descemetorhexis and insertion of the donor endothelial disk.
منابع مشابه
Air-Assisted Descemet Stripping Automated Endothelial Keratoplasty with Posterior Chamber Fixation of an Aphakic Iris-Claw Lens
Endothelial keratoplasty (EK) is the most exciting recent development in corneal transplantation. It has experienced surprisingly rapid growth in a very short period of time. One of the indications for EK is pseudophakic bullous keratopathy. However, concomitant intraocular lens (IOL) exchange, if indicated, may prove challenging. Some surgeons routinely perform IOL exchange with a scleral-fixa...
متن کاملManagement of angle-supported intraocular lens and iridectomy in Descemet-stripping endothelial keratoplasty.
PROBLEM Effective tamponade of a Descemet-stripping endothelial keratoplasty graft with a gas bubble requires that there is no route for the bubble to escape into the posterior chamber. SOLUTION Exchange the angle-supported anterior-chamber intraocular lens (IOL) for an iris-enclaved Artisan IOL and position the IOL haptics over the peripheral iridectomy to occlude it to the extent that no ga...
متن کاملDescemet’s Stripping with Automated Endothelial Keratoplasty (DSAEK) in Patients with Black Diaphragm Intraocular (BDI) Lens
A stable anterior chamber is a crucial factor to DSAEK. In aniridic patients with BDI lens, the anterior and posterior segment has direct communication at the periphery of the BDI lens. Maintenance of the air bubble in the anterior chamber would be problematic. Pressure equilibrium must be established on both sides of the BDI lens before the air bubble is introduced into the anterior chamber. C...
متن کاملImplantation of foldable posterior chamber intraocular lens in aphakic vitrectomized eyes without capsular support Implantação lente intraocular dobrável de câmara posterior em olhos afácicos vitrectomizados sem apoio capsular
The capsule of the crystalline lens, if sufficiently present, is used as a support tissue for intraocular lens (IOL) implantation surgery performed on vitrectomized eyes. Eye trauma or iatrogenic damage during complicated cataract surgery, loss of position and zonule connections of the crystalline lens, and IOL via dislocation may cause loss of support tissue for lens capsule implantation prior...
متن کاملIris-claw, retropupillary-fixated, aphakic intraocular lens implantation for traumatic aphakia following penetrating keratoplasty.
We report the correction of aphakia using an iris-claw, aphakic intraocular lens (IOL) fixated in a retropupillary location in a 17-year-old young man who suffered blunt trauma to his eye 5 months after penetrating keratoplasty (PKP). There were no intraoperative complications. At 21 months after implantation, the patient's uncorrected distance visual acuity was 20/28; his corrected distance vi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 37 2 شماره
صفحات -
تاریخ انتشار 2011