A Genomics-Based Model for Prediction of Severe Bioprosthetic Mitral Valve Calcification

نویسندگان

  • Anastasia V. Ponasenko
  • Maria V. Khutornaya
  • Anton G. Kutikhin
  • Natalia V. Rutkovskaya
  • Anna V. Tsepokina
  • Natalia V. Kondyukova
  • Arseniy E. Yuzhalin
  • Leonid S. Barbarash
چکیده

Severe bioprosthetic mitral valve calcification is a significant problem in cardiovascular surgery. Unfortunately, clinical markers did not demonstrate efficacy in prediction of severe bioprosthetic mitral valve calcification. Here, we examined whether a genomics-based approach is efficient in predicting the risk of severe bioprosthetic mitral valve calcification. A total of 124 consecutive Russian patients who underwent mitral valve replacement surgery were recruited. We investigated the associations of the inherited variation in innate immunity, lipid metabolism and calcium metabolism genes with severe bioprosthetic mitral valve calcification. Genotyping was conducted utilizing the TaqMan assay. Eight gene polymorphisms were significantly associated with severe bioprosthetic mitral valve calcification and were therefore included into stepwise logistic regression which identified male gender, the T/T genotype of the rs3775073 polymorphism within the TLR6 gene, the C/T genotype of the rs2229238 polymorphism within the IL6R gene, and the A/A genotype of the rs10455872 polymorphism within the LPA gene as independent predictors of severe bioprosthetic mitral valve calcification. The developed genomics-based model had fair predictive value with area under the receiver operating characteristic (ROC) curve of 0.73. In conclusion, our genomics-based approach is efficient for the prediction of severe bioprosthetic mitral valve calcification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Degenerative processes in bioprosthetic mitral valves in juvenile pigs

BACKGROUND Glutaraldehyde-treated bioprosthetic heart valves are commonly used for replacement of diseased heart valves. However, calcification and wear limit their durability, and the development of new and improved bioprosthetic valve designs is needed and must be evaluated in a reliable animal model. We studied glutaraldehyde-treated valves 6 months after implantation to evaluate bioprosthet...

متن کامل

Transcather Mitral Valve-in-Valve Replacement: The New Frontier in Heart Valve Therapy

Introduction: Surgical valve replacement is not always feasible in patients with severe mitral regurgitation from a failing bioprosthetic valve or severe mitral annular calcification. Off-label use of transcatheter aortic valves has been described in the literature as a possible method of valve replacement for this patient population. We review the literature on this practice as well as present...

متن کامل

Relationship Between Calcium-phosphorous Product, Native and Bioprosthetic Mitral Valve Calcifications

Calcification is a common cause of failure of natural and bioprosthetic valves (BPV). Prior research on patients with chronic kidney disease identified increased calcium-phosphorus (Ca-P) product as a risk factor for both arterial and valvular calcifications, an aspect not thoroughly investigated in general population. The aims of our study were to analyse the functional impact of native and bi...

متن کامل

Evaluation of stentless kangaroo aortic valves in the mitral position of juvenile sheep.

BACKGROUND AND AIM OF THE STUDY The performance and longevity of bioprosthetic heart valves are limited by tissue calcification and degeneration after implantation. Experimental valve replacement in large animal models forms an important component of the preclinical evaluation of these bioprosthetic heart valves. The study aim was to assess the feasibility of a mitral model for stentless valves...

متن کامل

Intra-atrial placement of a mitral prosthesis in a patient with severe mitral annulus calcification: a case report.

An 88-year-old woman presented with increasing dyspnea and angina. She was found to have severe aortic stenosis, 2-vessel coronary artery disease, and severe mitral regurgitation. During surgery the patient was noted to have such severe mitral annular calcification that performing a conventional mitral valve replacement would have significantly increased the operative risk. Instead, an 8-mm Dac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016