Quantification of saxitoxin and neosaxitoxin in human urine utilizing isotope dilution tandem mass spectrometry.
نویسندگان
چکیده
Saxitoxin and neosaxitoxin are potent neurotoxins that can cause paralytic shellfish poisoning when consumed. A new assay is presented here to quantify saxitoxin (STX) and neosaxitoxin (NEO) in human urine samples. Sample preparation of 500-microL samples included the use of weak-cation-exchange solid-phase extraction in a multiplexed 96-well format. Extracts were preconcentrated and analyzed via 10-min hydrophilic interaction liquid chromatography followed by electrospray ionization. Protonated molecular ions were quantified via multiple reaction monitoring mode in a Qtrap mass spectrometer. The method uses novel 15N7-isotopically enriched STX and NEO internal standards. Method validation included the characterization of two enriched urine pools. The lowest reportable limits for STX and NEO were 4.80 and 10.1 ng/mL, respectively, using both quantification and confirmation ions. These two toxins were not detected in a reference range of humans who consumed seafood in the preceding 72 h, suggesting that few false positives would occur when trying to identify people exposed to STX or NEO.
منابع مشابه
Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method Coupled with Dispersive Solid-Phase Extraction for Simultaneous Quantification of Eight Paralytic Shellfish Poisoning Toxins in Shellfish
In this study, a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for simultaneous determination of eight paralytic shellfish poisoning (PSP) toxins, including saxitoxin (STX), neosaxitoxin (NEO), gonyautoxins (GTX1-4) and the N-sulfo carbamoyl toxins C1 and C2, in sea shellfish. The samples were extracted by acetonitrile/water (80:20, v/v) with ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملGas-phase dissociation reactions of protonated saxitoxin and neosaxitoxin.
The aim of this study was to investigate the behavior of the protonated paralytic shellfish poisons saxitoxin (STX) and neosaxitoxin (NEO) in the gas-phase after ion activation using different tandem mass spectrometry techniques. STX and NEO belong to a group of neurotoxins produced by several strains of marine dinoflagellates. Their chemical structures are based on a tetrahydropurine skeleton ...
متن کاملDetermination of creatinine in human urine with flow injection tandem mass spectrometry.
BACKGROUND/AIMS Excretion of urinary compounds in spot urine is often estimated relative to creatinine. For the growing number of liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays of urine-excreted molecules, a fast and accurate method for determination of creatinine is needed. METHODS A high-throughput flow injection tandem mass spectrometry method for exact quantitation of cr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of analytical toxicology
دوره 33 1 شماره
صفحات -
تاریخ انتشار 2009