Biphasic versus monophasic shock waveform for conversion of atrial fibrillation.

نویسندگان

  • Robert W Rho
  • Richard L Page
چکیده

Cardioversion of atrial fibrillation (AF) using traditional monophasic shock waveform is unsuccessful in up to 20% of cases, and often requires several shocks of up to 360 J. Based on the success with biphasic shock waveform in converting ventricular fibrillation, it was postulated that biphasic shocks would allow cardioversion with lower energy. In a international multicenter, double-blind, randomized trial of 203 patients, damped sine wave monophasic shocks were compared with impedance-compensated truncated exponential biphasic waveform shocks. Patients received up to five shocks: 100 J, 150 J, 200 J, a fourth shock at maximum output for the initial waveform (200 J biphasic, 360 J monophasic) and a final cross-over shock at maximum output of the alternate waveform. For each energy level, the biphasic waveform compared favorably to the monophasic waveform in successful cardioversion (100 J: 60% versus 22%, P < 0.0001; 150 J: 77% versus 44%, p < 0.0001; 200 J: 90% versus 53%, p < 0.0001). Success with 200 J biphasic was equivalent to 360 J monophasic shock (91% versus 85%, p = 0.29). Patients randomized to biphasic waveform required fewer shocks and lower total energy delivered; in addition, this waveform was associated with less dermal injury and no blistering. Biphasic shocks converted AF present for less than 48 hours with 80% efficacy, but conversion of AF present for more than 48 hours and more than 1 year the success rate was only 63 and 20%, respectively. The results of this study is similar to other investigations comparing biphasic and monophasic shock waveforms for conversion of atrial fibrillation. We recommend starting with biphasic energy of 100 J for atrial fibrillation of less than 48 hours duration, but using higher energies (150 J, 200 J or greater) when AF has been present for longer periods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CARDIOVASCULAR MEDICINE Comparison of monophasic and biphasic shocks for transthoracic cardioversion of atrial fibrillation

Objective: To compare the efficacy of cardioversion in patients with atrial fibrillation between monophasic damped sine waveform and rectilinear biphasic waveform shocks at a high initial energy level and with a conventional paddle position. Design: Prospective randomised study. Patients and setting: 227 patients admitted for cardioversion of atrial fibrillation to a tertiary referral centre. R...

متن کامل

Comparison of monophasic and biphasic shocks for transthoracic cardioversion of atrial fibrillation.

OBJECTIVE To compare the efficacy of cardioversion in patients with atrial fibrillation between monophasic damped sine waveform and rectilinear biphasic waveform shocks at a high initial energy level and with a conventional paddle position. DESIGN Prospective randomised study. PATIENTS AND SETTING 227 patients admitted for cardioversion of atrial fibrillation to a tertiary referral centre. ...

متن کامل

Transthoracic cardioversion of atrial fibrillation: comparison of rectilinear biphasic versus damped sine wave monophasic shocks.

BACKGROUND Clinical studies have shown that biphasic shocks are more effective than monophasic shocks for ventricular defibrillation. The purpose of this study was to compare the efficacy of a rectilinear biphasic waveform with a standard damped sine wave monophasic waveform for the transthoracic cardioversion of atrial fibrillation. METHODS AND RESULTS In this prospective, randomized, multic...

متن کامل

Comparing the efficacy and safety of a novel monophasic waveform delivered by the passive implantable atrial defibrillator with biphasic waveforms in cardioversion of atrial fibrillation.

BACKGROUND The passive implantable atrial defibrillator (PIAD) (with no battery or discharging capacitor and powered transcutaneously by radio-frequency energy) delivering a novel monophasic low-tilt waveform is more efficacious than the standard monophasic waveform at atrial defibrillation. Standard biphasic (STB) waveforms, however, are more efficacious and safer than monophasic waveforms. Th...

متن کامل

Biphasic waveform shocks were effective and efficient for cardioversion of atrial fibrillation.

I n t e r v e n t i o n Patients were allocated to impedance-compensated truncated exponential biphasic shocks (n = 96) or damped sine wave monophasic shocks (n = 107). Patients received up to 5 shocks: 100 joules (J), 150 J, 200 J, a fourth shock at maximum output for the initial waveform (200 J biphasic, 360 J monophasic), and a final crossover at maximum output of the alternate waveform. M a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiac electrophysiology review

دوره 7 3  شماره 

صفحات  -

تاریخ انتشار 2002