Establishment of a Procedure to Calculate the Measurement Uncertainties in RadiationSurvey Meters Calibration
نویسنده
چکیده
INTRODUCTION Error analysis works with the fact that any measurement procedure has imperfections that give rise to an error in the measurement result. Error is the result of a measurement minus the true value of the measurand. There are many good books on this subject (1,2). Since the true value cannot be determined, in practice a conventional true value is used. Based on these errors it is constructed a parameter associated with the result of a measurement that characterizes the dispersion of the values that could reasonably be attributed to the measurand and is called uncertainty (3). It’s quite important to know the uncertainty in a measurement, mainly in a calibration laboratory, because it is the clear expression of the capability and quality of theirs services (4). The Calibration Laboratory of IPEN (LCI/IPEN) calibrates more than one thousand gamma ray survey meters a year, beside other kinds of radiotherapy, diagnostic radiology and radiation protection instruments. In the gamma ray survey meter calibration procedure there are two values that have to get theirs uncertainties clearly known: measurements in the instrument under calibration and the true value. The uncertainty in the instrument under calibration is normally an A kind and is obtained by a series of measurements, at least ten, and then its standard deviation is multiplied by the t-factor to express the confidence level of the instrument (1). For the physical quantities exposure, absorbed dose or dose equivalent rates the true value is obtained through the indirect measurements performed with a reference ionization chamber. It is measured the integral of electrical current in a time interval, a charge, (Q±∆Q), formed in the active volume of the chamber when it is submitted to the radiation in a precisely distance (x±∆x) and instant (t±∆t). The measurement with the instrument under calibration (and its uncertainty) is compared with the true value (and its uncertainty) and if the normalization (57) is not obeyed adjustments are made in the instrument. The LCI has a reference (600cm) cylinder ionization chamber (Nuclear Enterprises Ltd. model 2511/3) traceable to the Brazilian Secondary Standard Dosimetry Laboratory (SSDL) which is traceable to the BIPM. Annually the beam dosimetry is performed using this ionization chamber and the results are used for the true values determination for calibration purposes. The uncertainties present in every direct or indirect measurement during the calibration procedure must be evaluated for purposes of laboratory quality control. All calculation steps in the propagation of errors are presented in this work starting from the ionization chamber charge measured with the reference instrument. Such propagation was made in space and time, considering even the pressure and temperature uncertainties. The propagation was necessary in space, because the ionization chamber measurements were performed at only one space position, that is (1,000±0,005)m. Actually we use a new procedure based in five measured positions and it will be published soon. The time propagation was essential due to the fact that the activity is a peculiar physical quantity, which changes with the time according to precise relations for a specific radionuclide. Nowadays the achievement of calibration laboratory quality systems requires the expression of all uncertainties and the procedure used to evaluate it. The FORTRAN program was used to calculate the true values, theirs uncertainties and an example of this procedure in the case of the calibration of a typical scale of a portable radiation survey meter is presented.
منابع مشابه
Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملUncertainty Calculation for Spectral-Responsivity Measurements
This paper discusses a procedure for measuring the absolute spectral responsivity of optical-fiber power meters and computation of the calibration uncertainty. The procedure reconciles measurement results associated with a monochromator-based measurement system with those obtained with laser sources coupled with optical fiber. Relative expanded uncertainties based on the methods from the Guide ...
متن کامل[Survey and analysis of radiation safety management systems at medical institutions--second report: radiation measurement, calibration of radiation survey meters, and periodic check of installations, equipment, and protection instruments].
We carried out a questionnaire survey to determine the actual situation of radiation safety management measures in all medical institutions in Japan that had nuclear medicine facilities. The questionnaire consisted of questions concerning the evaluation of shielding capacity; radiation measurement; periodic checks of installations, equipment, and protection instruments; and the calibration of r...
متن کاملDesign and construction of 6-component balance dynamometer for measurement of the forces, moments andmotions of ship models in the towing tank
During design spiral of a merchant ship or a naval vessel, it is important to perform towing tank tests in order to measure its performance either in calm water maneuvers or in waves for seakeeping performance. Also, to optimize a hydrodynamic design, towing tank tests are advantageous.This article presents the results of an applied research project. The objective of this project is to design a...
متن کاملInfrared Thermopile Temperature Measurement Technique in Microwave Heating Systems
Temperature measurement in microwave systems is essential for thermally driven processes, namely, catalytic reactions and ceramic sintering. Although, the application of direct thermometry methods, namely, thermocouples, have been commonly articulated in the available literature, however, contacted temperature measurement mechanisms have aroused concerns associated with the disruption of the el...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2000