An ion trap for cooling MCIs with cold positrons

نویسندگان

  • Takao M. Kojima
  • Nagayasu Oshima
  • Dana Dumitriu
  • Hitoshi Oyama
  • Akihiro Mohri
  • Yasunori Yamazaki
چکیده

An electro-magnetic trap for cooling multi-charged ions (MCIs) with cold positrons has been designed and is now under construction. A 5-tesla superconducting solenoid in which the trap will be installed has been constructed and installed in the experimental hall. The cooling scheme of MCIs is as follows: 1) loading electrons in the trap on which an electric harmonic potential is applied, 2) cooling of trapped electrons via emission of orbital radiation of cyclotron motion, 3) injection and trapping of positrons through collisions with the pre-loaded electrons and then cyclotron radiation, 4) injection and trapping of MCIs followed by cooling with positrons. The cooled MCIs will be extracted as a low energy MCI beam with well-defined energy, which allows ultra-slow collision experiments with mono-energetic MCIs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Antihydrogen trapping assisted by sympathetically cooled positrons

Antihydrogen, the bound state of an antiproton and a positron, is of interest for use in precision tests of natureʼs fundamental symmetries. Antihydrogen formed by carefully merging cold plasmas of positrons and antiprotons has recently been trapped in magnetic traps. The efficiency of trapping is strongly dependent on the temperature of the nascent antihydrogen, which, to be trapped, must have...

متن کامل

A Laser-cooled Positron Plasma

We present results on trapping and cooling of positrons in a Penning trap. Positrons from a 2 mCi Na source travel along the axis of a 6 T magnet and through the trap after which they strike a Cu reflection moderator crystal. Up to a few thousand positrons are trapped and lose energy through Coulomb collisions (sympathetic cooling) with laser-cooled Be. By imaging the Be laser-induced fluoresce...

متن کامل

Vibrational cooling in a cold ion trap: vibrationally resolved photoelectron spectroscopy of cold C60(-) anions.

We demonstrate vibrational cooling of anions via collisions with a background gas in an ion trap attached to a cryogenically controlled cold head (10-400 K). Photoelectron spectra of vibrationally cold C60(-) anions, produced by electrospray ionization and cooled in the cold ion trap, have been obtained. Relative to spectra taken at room temperature, vibrational hot bands are completely elimina...

متن کامل

Development of a low-temperature photoelectron spectroscopy instrument using an electrospray ion source and a cryogenically controlled ion trap.

The ability to control ion temperatures is critical for gas phase spectroscopy and has been a challenge in chemical physics. A low-temperature photoelectron spectroscopy instrument has been developed for the investigation of complex anions in the gas phase, including multiply charged anions, solvated species, and biological molecules. The new apparatus consists of an electrospray ionization sou...

متن کامل

Driven production of cold antihydrogen and the first measured distribution of antihydrogen states.

Cold antihydrogen is produced when antiprotons are repeatedly driven into collisions with cold positrons within a nested Penning trap. Efficient antihydrogen production takes place during many cycles of positron cooling of antiprotons. A first measurement of a distribution of antihydrogen states is made using a preionizing electric field between separated production and detection regions. Survi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000