A miniature TDCR system dedicated to in-situ activity assay.

نویسندگان

  • Lena Johansson
  • Eleanor Bakhshandeiar
  • Andy Pearce
  • Sean Collins
  • Pascal Orlandini
  • John Sephton
چکیده

In the framework of the European Metrology Research Programme (EMRP), the Joint Research Project MetroFission has a dedicated work package for the development of a portable Triple-to-Double-Coincidence-Ratio (TDCR) system dedicated to in-situ activity measurements of low-energy beta emitters arising from the operation of the next generation of nuclear power plants. In the design phase of the NPL version of the mini-TDCR, a wide range of metrological aspects and detector types was considered. This paper summarizes these aspects of design, in the light of previous experience with the primary TDCR system at NPL. For example, in this miniature version of the TDCR, the optical chamber was simplified and cylindrical geometry was deemed sufficient. The reflectivity of the surface was increased by painted layers of Spectraflect(®), a specially formulated barium sulphate coating with high reflectivity across a wide range of wave lengths including UV. This option was chosen rather than the high performing and more expensive Spectralon(®) material used for the primary NPL TDCR. The miniature TDCR system is intended for on-site monitoring and will not require as high a performance as the primary system. Other factors that were considered included sample changing, light tightness, type of photo detector, method for varying the detection efficiency, shielding and the possible addition of an internal gamma-ray source for determination of the quench parameter of the source. In this version, the sample changing is performed using a piston and an automatic shutter. Significant design effort has been applied to ensure minimal ingress of light from the piston. Efficiency variation is accomplished by increasing the vertical displacement of the vial. Provision has been made to automate this at a later stage. Maximum light transmission to the photo-multiplier tubes is obtained at the "zero" reference height. Validation measurements were successfully performed using four different radionuclides: (3)H, (241)Pu, (63)Ni, and (99)Tc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Sensitive Neutralization Assay for Influenza C Viruses Based on the Acetylesterase Activity HEF Glycoprotein

Influenza C virus possesses specific neuraminate-O-acetylesterase as a receptor-destroying function. This enzymatic activity of the viral glycoprotein HEF (Hemagglutinin, esterase activity and fusion factor) can be visualized in situ by the use of distinct color substrates. Hereby the localization, as well as the quantity of synthesized HEF protein is detectable. We further developed the estera...

متن کامل

Using Miniature Cone Penetration Test (Mini-CPT) to determine engineering properties of sandy soils

In-situ testing techniques have proven to be successful in improving the speed and reliability of geotechnical investigations. One of the most common in-situ methods in engineering geology and site investigation is Cone Penetration Test (CPT), which is mainly used for characterization of soils, as it is a robust, simple, fast, reliable and economic test that can provide continuous soundings of ...

متن کامل

Designing an Am-Be miniature neutron source

Background: Miniature neutron sources with high neutron flux have abundant applications in medicine, industry and researches. The most important general characteristic of miniature neutron sources is their diameter which is 3mm in average. In this research, we have surveyed and designed an Am-Be miniature neutron source fabrication. Materials and Methods: This investigation resulted in creation...

متن کامل

Functional analysis of the tdcABC promoter of Escherichia coli: roles of TdcA and TdcR.

The efficient expression of the tdc operon of Escherichia coli requires the products of two regulatory genes, tdcR and tdcA. We have identified the transcription site of tdcR by primer extension mapping and established the translation start site of TdcR by mutational analysis of its reading frame. In a tdcR tdcABC deletion strain, tdcR+ promoted high-level LacZ expression from a lambda tdcAB-la...

متن کامل

Norfloxacin loaded pH triggered nanoparticulate in situ gel for extraocular bacterial infections: Optimization, ocular irritancy and corneal toxicity

In order to achieve prolong corneal contact time of norfloxacin(NFX) for treatment of extra ocular diseases, a pH triggered nanoparticulate in situ gelling system was designed to explore dual advantage of nanoparticles and in situ gelling system, for its ocular delivery. NFX loaded nanocarriers were developed by ionotropic gelation technique using chitosan as a matrix forming polymer, cross-lin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 87  شماره 

صفحات  -

تاریخ انتشار 2014