"Motion-frozen" display and quantification of myocardial perfusion.

نویسندگان

  • Piotr J Slomka
  • Hidetaka Nishina
  • Daniel S Berman
  • Xingping Kang
  • Cigdem Akincioglu
  • John D Friedman
  • Sean W Hayes
  • Usaf E Aladl
  • Guido Germano
چکیده

UNLABELLED Gated myocadial perfusion SPECT (MPS) incorporates functional and perfusion information of the left ventricle (LV). To improve the image quality and accuracy of gated MPS we propose to eliminate the influence of cardiac LV motion in the display and quantification by a novel "motion-frozen" (MF) technique. METHODS Three-dimensional LV contours were identified on images of the individual time phases. Three-dimensional phase-to-phase motion vectors were derived by sampling of the epi- and endocardial surfaces. A nonlinear image warping (thin-plate spline) was applied to warp all image phases to fit the end-diastolic (ED) phase. Warped images were created to provide the LV image in the ED phase but containing counts from an arbitrary number of time intervals. MF quantification has been performed using the same phase-to-phase motion vectors. MF normal perfusion limits were created from (99m)Tc sestamibi gated MPS studies of 40 females and 40 males with low likelihood (<5%) of coronary artery disease. All MF processing was completely automated. In the initial evaluation, we assessed the display quality and quantification of stress images using MF processing in 51 consecutive patients with 16-frame electrocardiographic gating and available coronary angiography. RESULTS The display quality was significantly better for MF images as assessed visually. The MF images had the appearance of ED frames but were less noisy and of higher resolution than the summed images. MF images had higher maximum count values in the LV (116% +/- 6%) and higher contrast (12.5 +/- 7.7 vs. 9.5 +/- 3.2) than the corresponding summed images. The area under the receiver operator characteristic curve for prediction of stenoses > or = 70% by the MF method was 0.92 +/- 0.04 versus 0.89 +/- 0.04 by standard quantification (P = not significant). The computation time for automated MF quantification and warping was <25 s for each case. CONCLUSION We have developed a novel technique for display and quantification of gated myocardial perfusion images, which retrospectively eliminates blur due to cardiac motion. Such processing of gated MPS appears to improve the effective resolution of images. Initial evaluation indicates that it may improve the accuracy of gated MPS in detection of coronary artery disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

Comparison of the myocardial perfusion and wall motion results by ECG-Gated 99mTc-MIBI SPECT, before and after CABG for evaluation of myocardial viability [Persian]

It is of value to determine the amount of viable myocardial tissue in patients suffering from chronic coronary artery disease and ventricular dysfunction. Having the capability of evaluating both myocardial perfusion and function, simultaneously, myocardial scanning by ECG-Gated is an appropriate method for this purpose. The aim of this study was to compare the results of myocardial perfu...

متن کامل

Assessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]

Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 45 7  شماره 

صفحات  -

تاریخ انتشار 2004