Comparison of two rapid tests for anti-phenolic glycolipid-I serology in Brazil and Nepal.

نویسندگان

  • Mariane Martins de Araújo Stefani
  • Adriano Badotti Grassi
  • Lucas Henrique Sampaio
  • Ana Lúcia Osório Maroclo de Sousa
  • Maurício Barcelos Costa
  • Pauline Scheelbeek
  • Kapil D Neupane
  • Deanna A Hagge
  • Murdo Macdonald
  • Sang-Nae Cho
  • Linda Oskam
  • Samira Bührer-Sékula
چکیده

The diagnosis of leprosy continues to be based on clinical symptoms and early diagnosis and treatment are critical to preventing disability and transmission. Sensitive and specific laboratory tests are not available for diagnosing leprosy. Despite the limited applicability of anti-phenolic glycolipid-I (PGL-I) serology for diagnosis, it has been suggested as an additional tool to classify leprosy patients (LPs) for treatment purposes. Two formats of rapid tests to detect anti-PGL-I antibodies [ML immunochromatography assay (ICA) and ML Flow] were compared in different groups, multibacillary patients, paucibacillary patients, household contacts and healthy controls in Brazil and Nepal. High ML Flow intra-test concordance was observed and low to moderate agreement between the results of ML ICA and ML Flow tests on the serum of LPs was observed. LPs were "seroclassified" according to the results of these tests and the seroclassification was compared to other currently used classification systems: the World Health Organization operational classification, the bacilloscopic index and the Ridley-Jopling classification. When analysing the usefulness of these tests in the operational classification of PB and MB leprosy for treatment and follow-up purposes, the ML Flow test was the best point-of-care test for subjects in Nepal and despite the need for sample dilution, the ML ICA test yielded better performance among Brazilian subjects. Our results identified possible ways to improve the performance of both tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The ML flow test as a point of care test for leprosy control programmes: potential effects on classification of leprosy patients.

OBJECTIVE To evaluate the use of the ML Flow test as an additional, serological, tool for the classification of new leprosy patients. DESIGN In Brazil, Nepal and Nigeria, 2632 leprosy patients were classified by three METHODS : (1) as multibacillary (MB) or paucibacillary (PB) according to the number of skin lesions (WHO classification), (2) by slit skin smear examination, and (3) by serolo...

متن کامل

A comparison of ML Flow serology and slit skin smears to assess the bacterial load in newly diagnosed leprosy patients in Brazil.

INTRODUCTION The ML Flow test is an immunochromatographic assay that detects IgM antibodies against M. leprae-specific anti-phenolic glycolipid I (PGL-I). In addition to slit skin smears stained by the Ziehl-Neelsen technique, it can be helpful in the operational classification of leprosy patients for treatment purposes. OBJECTIVE This work studied the relationship between antibody levels as ...

متن کامل

Factors associated with anti-phenolic glycolipid-I seropositivity among the household contacts of leprosy cases

BACKGROUND The diagnosis of leprosy is based on clinical symptoms of the disease, which may not be sufficient to ensure early diagnosis. The development of effective tools for the early detection of infection, such as rapid tests that can be applied by non-specialists for early-stage leprosy identification, has been considered a research priority and may contribute to overcoming the complicatio...

متن کامل

Risk-benefit assessment of Bacillus Calmette-Guérin vaccination, anti-phenolic glycolipid I serology, and Mitsuda test response: 10-year follow-up of household contacts of leprosy patients.

INTRODUCTION Despite multidrug therapy, leprosy remains a public health issue. The intradermal Bacillus Calmette-Guérin (BCG) vaccine, Mitsuda test (lepromin skin test), and anti-phenolic glycolipid I (PGL-I) serology are widely used in leprosy studies and have shown great epidemiological value. METHODS This longitudinal study evaluated the relative risks and benefits of these three tools by ...

متن کامل

Anti-phenolic glycolipid-I (PGL-I) determination using blood collection on filter paper in leprosy patients.

The authors studied 70 leprosy patients and 20 normal individuals, comparing the traditional sera collection method and the finger prick blood with the conservation on filter paper for specific antibodies against the native phenolic glycolipid-I (PGL-I) from Mycobacterium leprae. The finger prick blood dried on filter paper was eluated in phosphate buffer saline (PBS) containing 0.5% gelatin. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Memorias do Instituto Oswaldo Cruz

دوره 107 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2012