Flexible and Efficient Data Acquisition Technique for 3D-FSE-IDEAL
نویسندگان
چکیده
A. J. Madhuranthakam, H. Yu, A. Shimakawa, M. P. Smith, S. B. Reeder, N. M. Rofsky, C. A. McKenzie, and J. H. Brittain MR Applied Science Lab, GE Healthcare, Boston, MA, United States, MR Applied Science Lab, GE Healthcare, Menlo Park, CA, United States, Radiology, Beth Israel Deaconess Medical Center, Boston, MA, United States, Harvard Medical School, Boston, MA, United States, Radiology, Medical Physics, Biomedical Engineering and Medicine, University of Wisconsin, Madison, WI, United States, Medical Biophysics, University of Western Ontario, London, Ontario, Canada, MR Applied Science Lab, GE Healthcare, Madison, WI, United States
منابع مشابه
Evaluation of Intraneural Ganglion Cysts Using 3D FSE-Cube
Purpose: It is often difficult to definitively diagnose intraneural ganglion cysts with conventional MR imaging and to identify the origin of the cyst in a joint via what may often be a subtle connection [1]. Identification of the joint connection has important clinical implications if it is not addressed surgically, such as: cyst recurrence, incomplete patient recovery, and suboptimal operativ...
متن کاملIsotropic Imaging of the Wrist at 1.5T using 3D-FSE-Cube
INTRODUCTION: MRI with two-dimensional fast spin-echo (2D-FSE) requires multiple acquisition planes because of slice gaps and partial-volume artifacts. Volumetric acquisitions with isotropic resolution overcome these limitations, allowing reformations in arbitrary imaging planes from a single acquisition [1-3]. A 3D isotropic fast spin-echo sequence (3D-FSE-Cube) was compared with conventional ...
متن کاملThree-dimensional fast spin-echo MR of the inner ear: ultra-long echo train length and half-Fourier technique.
We compared the image quality of the newly developed ultra-long echo train length (ETL) 3-D fast spin-echo (FSE) and half-Fourier technique, which is performed in less than 3 minutes, with the conventional 3D-FSE imaging technique, which takes 15 minutes, in assessing MR examinations of the inner ear. The new method's images were almost comparable to the conventional 3D-FSE images in depicting ...
متن کاملIsotropic MRI of the Upper Extremity with 3D-FSE-Cube
Introduction Musculoskeletal MRI is commonly done with two-dimensional fast-spin-echo (2D-FSE) and multiple acquisition planes. This results in anisotropic voxels, partial volume artifact and slice gaps. Three-dimensional fast-spin-echo (3D-FSE-Cube), allows for isotropic voxel acquisition with FSE contrast, diminishing the drawbacks of 2D-FSE while reducing exam time and allowing for image ref...
متن کاملFast decomposition of water and lipid using a GRASE technique with the IDEAL algorithm.
Three-point Dixon techniques achieve good lipid-water separation by estimating the phase due to field inhomogeneities. Recently it was demonstrated that the combination of an iterative algorithm (iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL)) with a fast spin-echo (FSE) three-point Dixon method yielded robust lipid-water decomposition. As an a...
متن کامل