Comparison of Intraocular Pressure Measurements in Healthy Pediatric Patients using Three Types of Tonometers
نویسندگان
چکیده
OBJECTIVES This study aimed to compare intraocular pressure (IOP) measurements in healthy pediatric patients using three types of tonometers. MATERIALS AND METHODS Seventy-eight eyes of 78 patients under the age of 18 who underwent a routine ophthalmologic examination were included in the study. IOP was measured using Tono-Pen (TP) tonometry, Goldmann applanation tonometry (GAT), and non-contact tonometry (NCT), consecutively. IOP was adjusted based on central corneal thickness (CCT). Patients with any ocular disorders other than a limited refractive error were excluded from the study. RESULTS The study consisted of 46 girls and 32 boys. The mean age was 12.6±2.7 (range: 5-17) years. The mean CCT was 559.3±35.3 µm. The mean refractive error was -0.50±1.70. The mean level of visual acuity was 0.98±0.1 (range: 0.3-1.0) using the Snellen chart. Significant differences were found between the measurement results of each of the three tonometric methods. Mean IOP was 12.1±2.2 mmHg for TP, 15.7±2.5 mmHg for GAT, and 17.1±3.1 mmHg for NCT. The correlations between measurement methods revealed that the highest correlation was between NCT and GAT (p<0.001, r=0.670). The second highest correlation was between NCT and TP (p<0.001, r=0.477). The lowest correlation was between GAT and TP (p<0.001, r=0.403). A positive correlation was found between CCT and each IOP measurement method. CONCLUSION In pediatric patients, TP and NCT measurements were found to be positively correlated with GAT measurements. Because TP measurements were lower than GAT measurements and NCT measurements were higher than GAT measurements, patient follow-ups, treatment strategies, and surgery plans must be organized taking these differences into consideration.
منابع مشابه
Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملComparison of intraocular pressure measurements with the portable PT100 noncontact tonometer and goldmann applanation tonometry
PURPOSE Noncontact tonometers are useful when regulations preclude use of contact tonometers by medical students and other nonophthalmologists. Our study compared the measurements by the portable, noncontact tonometer (PT100) with Goldmann applanation tonometry (GAT). METHODS This was a prospective study of 98 eyes from 98 patients. Intraocular pressure (IOP) was measured by GAT and the PT100...
متن کامل[Comparison between Goldmann, Icare Pro and Corvis ST tonometry].
PURPOSE To compare intraocular pressure (IOP) between the new non-contact tonometer Corvis ST (CST), the Goldmann applanation tonometry (GAT) and Icare Pro rebound tonometer (PRO). METHODS A total of 178 eyes of 178 healthy subjects were selected for the study. Measurements of IOP were made in a random order with GAT, PRO and CST. Central corneal thickness (CCT) was determined by ultrasound p...
متن کامل[Comparison of dynamic contour tonometry (Pascal) with pneumotonometry and Goldmann tonometry].
PURPOSE To compare the intraocular pressure measurements as defined by the Pascal tonometer, the Goldmann tonometer and the pneumotonometer. METHODS This was an observational clinical study, which included two hundred and five randomly selected subjects recruited from the Ophthalmology Department. The intraocular pressure measurements were performed with each tonometry technique in a randomiz...
متن کاملAuthor’s response to reviews Title: Comparison of Intraocular Pressure as Measured by Three Different Non-contact Tonometers and Goldmann Applanation Tonometer for Non-glaucomatous Subjects Authors:
Title: Comparison of Intraocular Pressure as Measured by Three Different Non-contact Tonometers and Goldmann Applanation Tonometer for Non-glaucomatous Subjects Authors: Seung Pil Bang ([email protected]) Chong Eun Lee ([email protected]) Yu Cheol Kim ([email protected]) Version: 3 Date: 27 Jul 2017 Author’s response to reviews: Revision Letter Manuscript Number BOPH-D-17-00287 “Comparison of Int...
متن کامل