Pulse-inversion US imaging of testicular ischemia: quantitative and qualitative analyses in a rabbit model.

نویسندگان

  • Harriet J Paltiel
  • Leslie A Kalish
  • Ricardo A Susaeta
  • Ferdinand Frauscher
  • Patrick L O'Kane
  • Luiz G Freitas-Filho
چکیده

PURPOSE To quantitatively and qualitatively assess perfusion with pulse-inversion (PI) ultrasonography (US) in rabbit model of acute testicular ischemia. MATERIALS AND METHODS Institutional animal care committee approval was obtained. After 35 rabbits underwent unilateral spermatic cord occlusion, testicular Doppler US and contrast material-enhanced PI imaging were performed. Enhancement data yielded perfusion measurements including mean value during the first 10 seconds, mean value over entire recorded replenishment curve, and curve slope during the first 5 seconds. Calculated perfusion ratios were compared with radiolabeled microsphere-derived perfusion ratios. Two readers assessed testicular perfusion as none, possible, or definite and relative perfusion as greater to the right testis than to the left, greater to the left testis than to the right, or as equal to both testes. With kappa statistics, interobserver agreement for all imaging methods was determined. Association between qualitative perfusion categories and radiolabeled microsphere-based perfusion measurements was assessed. Quantitative and qualitative determinations of relative perfusion were compared with radiolabeled microsphere-based measurements. RESULTS Correlations between calculated and radiolabeled microsphere-based perfusion ratios were determined (r=0.49-0.64). Interobserver agreement for presence of perfusion was excellent (kappa=0.76), and that for relative perfusion assessment was good (kappa=0.55). Neither kappa value varied significantly with imaging method. The percentage of times a testis classified as having definite perfusion had greater perfusion as measured with radiolabeled microspheres than a testis classified as having no perfusion or possible perfusion was higher with PI imaging than with Doppler US (85%-98% vs 72%-89%). Identification of the testis with less perfusion was better with quantitative methods than with qualitative assessment of images by the readers (75%-79% vs 34%-60%, P<.004). CONCLUSION PI imaging, compared with conventional Doppler US methods, provides superior assessment of perfusion in the setting of acute testicular ischemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Curcumin Nanoparticles on the Tissue Oxidative Stress Following Testicular Torsion and Detorsion in Rat Model

Objective-The aim of the present study was to investigate the effects of curcumin nanoparticles (CNP) on stress oxidative following experimental ischemia-reperfusion injury in the rat testes. Design-Experimental Study Animals- Seventy-seven healthy male Wistar rats Procedures-The animals weighing approximately...

متن کامل

Effects of L-carnitine and betamethasone on ischemia-reperfusion injuries and sperm parameters following testicular torsion in a rat model

Testicular torsion is a consequence of spermatic cord twisting which causes progressive damage to the structure of the testis and reduces sperm quality and usually results in infertility. In the present study, with the assumption of the protective effects of L-carnitine and betamethasone against ischemia-reperfusion (IR) injuries, their effects on twisted testicles were evaluated and compared. ...

متن کامل

P-43: Short Term Effect of Oxytocin on Testis under Ischemia Reperfusion Injury

Background: The aim of this study was to investigate the short term protective effect of oxytocin on testicular ischemia reperfusion injury immediately after detorsion in a rat model. Materials and Methods: Twenty adult rats were randomly divided into four groups: Control, Ischemia- Reperfusion (IR), Oxytocin and IR+ Oxytocin. Testicular ischemia was achieved by torsion of the left testis 720° ...

متن کامل

The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence

  Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...

متن کامل

Antioxidant property of Plantago major leaf extracts reduces testicular torsion/detorsion-induced ischemia/reperfusion injury in rats

The present study was aimed to determine the protective effects of Plantago major L (PM) leaf extracts on the testicular torsion/detorsion (T/D)-induced ischemia/reperfusion (I/R) injury in rats. Twenty-four mature male Sprague-Dawley rats, weighing 200-220 g, were selected. They were randomly divided into four groups of six animals each: Sham (sham-operated rats; all the surg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 239 3  شماره 

صفحات  -

تاریخ انتشار 2006