Impact of Right Atrial Pressure on Fractional Flow Reserve Measurements: Comparison of Fractional Flow Reserve and Myocardial Fractional Flow Reserve in 1,600 Coronary Stenoses.

نویسندگان

  • Gabor G Toth
  • Bernard De Bruyne
  • Dan Rusinaru
  • Giuseppe Di Gioia
  • Jozef Bartunek
  • Mariano Pellicano
  • Marc Vanderheyden
  • Julien Adjedj
  • William Wijns
  • Nico H J Pijls
  • Emanuele Barbato
چکیده

OBJECTIVES This study sought to assess the impact of a wide range of mean right atrial pressure (Pra) on fractional flow reserve (FFR) measurements. BACKGROUND FFR invasively assesses the ischemic potential of coronary stenoses. FFR is calculated as the ratio of mean distal coronary pressure (Pd) to mean aortic pressure (Pa) during maximal hyperemia. The Pra is considered to have little impact if it is within normal range, so it is neglected in the formula. METHODS In 1,676 stenoses of 1,235 patients undergoing left-right heart catheterization for ischemic (642 [52%]) or valvular heart disease (593 [48%]), the authors compared the FFR values calculated without accounting for Pra (FFR= Pd/Pa) to the corresponding myocardial fractional flow reserve (FFRmyo) values accounting for Pra (FFRmyo = Pd - Pra/Pa - Pra). RESULTS The median Pra was 7 (interquartile range [IQR]: 5 to 10) mm Hg with a maximum of 27 mm Hg. The correlation and agreement between FFR and FFRmyo was excellent (R(2) = 0.987; slope 1.096 ± 0.003). The median FFR (0.85; IQR: 0.78 to 0.91) was slightly but statistically significantly higher than the median FFRmyo (0.83; IQR: 0.76 to 0.90; p < 0.001) with a median difference of 0.01 (IQR: 0.01 to 0.02). Values of FFR above the cutoff of 0.80 provided an FFRmyo ≤0.80 in 110 (9%) stenoses. No FFR value above 0.80 provided an FFRmyo ≤0.75. CONCLUSIONS The difference between FFR and FFRmyo was minimal even in patients with markedly increased Pra. FFR values above the gray zone (i.e., >0.80) did not yield values below the gray zone (i.e., ≤0.75) in any case, which suggests that the impact of right atrial pressure on FFR measurement is indeed negligible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation With Positron Emission Tomography

Background Experimental studies have shown that fractional flow reserve (defined as the ratio of maximal achievable flow in a stenotic area to normal maximal achievable flow) can be calculated from coronary pressure measurements only. The objectives of this study were to validate fractional flow reserve calculation in humans and to compare this information with that derived from quantitative co...

متن کامل

Repair of all the components of the syndrome of aortic regurgitation and VSD.

Heyndrickx GR. Intracoronary and intravenous adenosine 50-triphosphate, adenosine, papaverine, and contrast medium to assess fractional flow reserve in humans. Circulation 2003;107:1877–1883. 21. Pijls N, van Son J, Kirkeeide R, De Bruyne B, Gould K. Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenos...

متن کامل

Diastolic fractional flow reserve to assess the functional severity of moderate coronary artery stenoses: comparison with fractional flow reserve and coronary flow velocity reserve.

BACKGROUND Coronary blood flow occurs mainly during the diastolic phase of each cardiac cycle and is mainly dependent on diastolic driving pressure, especially in the left anterior descending coronary artery (LAD). We hypothesized that calculation of the ratio of the diastolic driving pressure of a stenotic LAD to its normal value, namely diastolic FFR (d-FFR), might provide precise insight int...

متن کامل

Letter by Layland et al regarding article, "Validation of intravascular ultrasound-derived parameters with fractional flow reserve for assessment of coronary stenosis severity".

To the Editor: We read with great interest the study by Kang et al 1 that explored the relationship between intravascular ultrasound parameters and fractional flow reserve (FFR) in the assessment of intermediate coronary stenoses. 1 We congratulate the authors, who concluded that lesions with a mean luminal area of Ͻ2.4 mm 2 had a high sensitivity and negative predictive value to predict FFR Ͻ0...

متن کامل

Results of fractional flow reserve measurement to evaluate nonculprit coronary artery stenoses in patients with acute coronary syndrome.

INTRODUCTION AND OBJECTIVES Multivessel disease is usually present in almost half of patients with acute coronary syndromes. Angiography is insufficiently accurate to decide on coronary revascularization in moderate nonculprit lesions. There is some debate about the usefulness of fractional flow reserve assessed by intracoronary pressure wire in acute coronary syndromes. We studied the results ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 9 5  شماره 

صفحات  -

تاریخ انتشار 2016