Flow velocity and predictors of a suboptimal coronary flow velocity reserve after coronary balloon angioplasty.

نویسندگان

  • M Albertal
  • E Regar
  • G Van Langenhove
  • S G Carlier
  • P Serrano
  • E Boersma
  • B Bruyne
  • C Di Mario
  • J Piek
  • P W Serruys
چکیده

AIMS This study was conducted to analyse flow velocity parameters and predictors of a suboptimal coronary flow reserve (<2.5) following balloon angioplasty. METHODS Two hundred and twenty-five patients underwent sequential intracoronary Doppler as part of the DEBATE I study. Of these, 183, with complete angiography and Doppler at the 6-month follow-up, were included. Univariate and multivariate logistic analysis was performed to identify independent predictors of post-procedural suboptimal coronary flow reserve, defined as coronary flow reserve <2.5. RESULTS Forty-eight per cent (n=88) of the patients achieved a suboptimal coronary flow reserve. These patients had higher baseline velocities (cm.s(-1)) before balloon angioplasty (18+/-9 vs 14+/-6, P=0.004), after balloon angioplasty (22+/-11 vs 14+/-5, P<0.001) and at follow-up (19+/-9 vs 16+/-6, P=0.011) than the optimal coronary flow reserve group. Although the suboptimal group had lower hyperaemic velocities (cm.s(-1)) after balloon angioplasty than the optimal group (42+/-17 vs 49+/-16, P=0.008), these velocities became similar at follow-up. Increasing age (odds ratio, OR 1.071, P=0.0002), female gender (OR 2.52, P=0.014) and increasing pre-procedural baseline average peak velocities (OR 1.056, P<0.001) were found to be independent predictors of a suboptimal coronary flow reserve following balloon angioplasty. CONCLUSION A suboptimal coronary flow reserve was associated with (1) a chronically elevated baseline average peak velocity (2) a transient deficit in the hyperaemic average peak velocity (3) the elderly, and female gender.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary hemodynamics of stent implantation after suboptimal and optimal balloon angioplasty.

OBJECTIVES This study was performed to evaluate hemodynamic alterations of stent implantation after Doppler flow-guided balloon angioplasty (BA). BACKGROUND There is controversy regarding the effect of stent implantation on coronary hemodynamics after suboptimal and optimal BA. METHODS A total of 523 of 620 patients underwent Doppler-guided BA in the setting of a multicenter study and were ...

متن کامل

Functional assessment of coronary stenosis: it does make sense, but why don't I do it more often?

and at 6 months follow-up. As in other studies, there was only moderate correlation between coronary flow velocity reserve and diameter stenosis in lesions of moderate severity and the cut-off of coronary flow velocity reserve was 1·9 for patients with intermediate lesions. There are some known limitations with the use of Doppler coronary flow velocity reserve determinations. To obtain a good s...

متن کامل

Immediate and long-term effect of balloon angioplasty or stent implantation on the absolute and relative coronary blood flow velocity reserve.

BACKGROUND There is controversy regarding the immediate and long-term effects of PTCA on the coronary flow reserve. METHODS AND RESULTS A total of 54 patients with 1-vessel disease and normal left ventricular function were studied after balloon angioplasty (n=34) or stent implantation (n=20). Distal coronary blood flow velocity reserve (CFR) was defined as the ratio of adenosine-induced hyper...

متن کامل

Intracoronary pressure and flow velocity with sensor-tip guidewires: a new methodologic approach for assessment of coronary hemodynamics before and after coronary interventions.

The use of miniaturized pressure and velocity sensors mounted on angioplasty guidewires allows the simultaneous measurement of coronary blood flow velocity and transstenotic pressure gradient, 2 parameters that, combined, should perfectly characterize stenosis hemodynamics. The aim of this article is assessment of the changes in coronary blood flow velocity observed with a Doppler-tipped angiop...

متن کامل

Coronary flow reserve in the contralateral artery increases after successful coronary angioplasty in patients with spontaneously visible collateral vessels.

OBJECTIVE To test the hypothesis that coronary flow reserve could increase in the angiographically normal contralateral artery after successful coronary angioplasty of an ipsilateral coronary artery. DESIGN Coronary flow reserve was estimated using a Doppler flow guide wire, by giving intracoronary adenosine in the contralateral artery, before and 15 minutes after the end of angioplasty. SE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 23 2  شماره 

صفحات  -

تاریخ انتشار 2002