Ventilation rate in office buildings and sick building syndrome.
نویسندگان
چکیده
OBJECTIVE To examine the relation between ventilation rate and occurrence of symptoms of the eyes, nose, throat, and skin as well as general symptoms such as lethargy and headache, often termed the sick building syndrome. METHODS A cross sectional population based study was carried out in 399 workers from 14 mechanically ventilated office buildings without air recirculation or humidification, selected randomly from the Helsinki metropolitan area. The ventilation type and other characteristics of these buildings were recorded on a site visit and the ventilation in the rooms was assessed by measuring the airflow through the exhaust air outlets in the room. A questionnaire directed at workers inquired about the symptoms and perceived air quality and their possible personal and environmental determinants (response rate 81%). The outcomes were weekly work related symptoms experienced during the previous 12 months and symptom groups defined either by their anatomical location or hypothesised mechanism. RESULTS In logistic regression analysis, the adjusted odds ratio (OR) for any symptom of interest was 3.03 (95% confidence interval (95% CI) 1.13 to 8.10) in the very low ventilation category of below 5 l/s per person and 2.24 (0.89 to 5.65) in the high ventilation category of over 25 l/s per person compared with the reference (15- < 25 l/s). The ORs for ocular (1.27, 1.11 to 1.46), nasal (1.17, 1.06 to 1.29), skin symptoms (1.18, 1.05 to 1.32), and lethargy (1.09, 1.00 to 1.19) increased significantly by a unit decrease in ventilation from 25 to 0 l/s per person. CONCLUSION The results suggest that outdoor air ventilation rates below the optimal (15 to 25 l/s per person) increase the risk of the symptoms of sick building syndrome with the sources of pollutants present in mechanically ventilated office buildings. The Finnish guideline value is 10 l/s per person.
منابع مشابه
Effective of Sick Building Syndrome on Irritation of the Eyes and Asthma
In this research, we investigated basic symptoms of syndrome in illnesses of sick buildings. We designed a questionnaire and asked from male of dormitory residence. Questions of the questionnaire were more about known symptoms of buildings (Shortness of breath, inflammation, swelling and burning eyes, runny nose, malaise and fatigue, drowsiness, headache) exacerbations time intervals in the res...
متن کاملEffective of Sick Building Syndrome on Irritation of the Eyes and Asthma
In this research, we investigated basic symptoms of syndrome in illnesses of sick buildings. We designed a questionnaire and asked from male of dormitory residence. Questions of the questionnaire were more about known symptoms of buildings (Shortness of breath, inflammation, swelling and burning eyes, runny nose, malaise and fatigue, drowsiness, headache) exacerbations time intervals in the res...
متن کاملRelationship Between Sick Building Syndrome With Headache and Drowsiness
Based on previous researches and current research indoor contaminations in most of the time were more than outdoor contaminations. In according to, most of our times have been spent in indoor environments (85-90%), therefore, it is necessary to investigate indoor environments. Symptoms of sick building syndrome are Headache, dizziness, drowsiness. Unknown reasons of disease above mentioned and ...
متن کاملRelationship Between Sick Building Syndrome With Headache and Drowsiness
Based on previous researches and current research indoor contaminations in most of the time were more than outdoor contaminations. In according to, most of our times have been spent in indoor environments (85-90%), therefore, it is necessary to investigate indoor environments. Symptoms of sick building syndrome are Headache, dizziness, drowsiness. Unknown reasons of disease above mentioned and ...
متن کاملمطالعه علائم سندرم ساختمان بیمار در کارکنان اداری سازمان بهداشت و درمان صنعت نفت
Background­ and objectives : Research has consistently shown that air quality personal factors and work related factors were the most effective parameters for sick building syndrome. Several epidemiological studies have been carried out to show the prevalence of the sick building syndrome among the office workers but less attention has been paid to the relation of the sick building s...
متن کاملSummary of human responses to ventilation.
UNLABELLED It is known that ventilation is necessary to remove indoor-generated pollutants from indoor air or dilute their concentration to acceptable levels. But as the limit values of all pollutants are not known the exact determination of required ventilation rates based on pollutant concentrations is seldom possible. The selection of ventilation rates has to be based also on epidemiological...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Occupational and environmental medicine
دوره 52 11 شماره
صفحات -
تاریخ انتشار 1995