Fully automated measurement of the modulation transfer function of charge-coupled devices above the Nyquist frequency.
نویسندگان
چکیده
The charge-coupled devices used in electron microscopy are coated with a scintillating crystal that gives rise to a severe modulation transfer function (MTF). Exact knowledge of the MTF is imperative for a good correspondence between image simulation and experiment. We present a practical method to measure the MTF above the Nyquist frequency from the beam blocker's shadow image. The image processing has been fully automated and the program is made public. The method is successfully tested on three cameras with various beam blocker shapes.
منابع مشابه
Comparative analysis of techniques for measuring the modulation transfer functions of charge-coupled devices based on the generation of laser speckle.
Two methods for measuring the modulation transfer function (MTF) of a charge-coupled device (CCD) that are based on the generation of laser speckle are analyzed and compared. The method based on a single-slit aperture is a quick method, although the measurements are limited to values of less than the Nyquist frequency of the device. The double-slit method permits the measurement of values of as...
متن کاملDefocusing Effect Studies in MTF of CCD Cameras Based on PSF Measuring Technique
Defocusing effects in modulation transfer function (MTF) measurement of charge coupled device (CCD) cameras is the main focus of current paper. We introduce measuring Point-spread function (PSF) in order to calculate the MTF and further more we will study the shape of MTF and its cut-off frequency by adjusting the lens focusing in different locations. A collimated white light LED by broadband s...
متن کاملInvestigation of a CCD modulation transfer function using the speckle method at different laser wavelengths and sub-windowing options
We have experimentally investigated the MTF of a scientific grade CCD, especially considering its behavior induced by different laser wavelengths (from 470 nm to 633 nm) and varying number of total charge transfers. The MTF measurements were performed using laser speckles and utilizing the single-slit method. The MTF of the sensor was examined from zero to the Nyquist frequency. The results obt...
متن کاملAnalytical Investigation of Frequency Behavior in Tunnel Injection Quantum Dot VCSEL
The frequency behavior of the tunnel injection quantum dot vertical cavitysurface emitting laser (TIQD-VCSEL) is investigated by using an analyticalnumericalmethod on the modulation transfer function. The function is based on therate equations and is decomposed into components related to different energy levelsinside the quantum dot and injection well. In this way, the effect of the tunnelingpr...
متن کاملDesign and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada
دوره 18 2 شماره
صفحات -
تاریخ انتشار 2012