Thermographical Measuring of the Skin Temperature Using Laser Needle Acupuncture in Preterm Neonates

نویسندگان

  • Wolfgang Raith
  • Gerhard Litscher
  • Iris Sapetschnig
  • Sebastian Bauchinger
  • Evelyne Ziehenberger
  • Wilhelm Müller
  • Berndt Urlesberger
چکیده

In children, laser acupuncture is used more often than needle acupuncture in Western countries, due to their aversion to needles. When applying laser acupuncture to premature babies and neonates, firstly the degree of the thermal increase to the skin has to be evaluated so as to guarantee safe application. The patients were premature neonates before their discharge from hospital. The measurements were carried out by means of a polygraphy while they were asleep shortly. The large intestine 4 acupoint (LI4, Hegu) was stimulated by a microlaser needle (10 mW, 685 nm) twice (5 and 10 min). Local thermographic pictures were taken with a thermal camera (Flir i5, Flir Systems Inc., Portland, USA), and the warmest point was determined and subsequently compared. The study included 10 premature neonates (7 male, 3 female). The measurements were carried out on the 33rd day of life (weight 2030 g, gestational age 36 + 3 weeks of pregnancy). In comparison to the initial temperature (32.9°C), after 5 minutes of stimulation (33.9°C) (P = 0.025) and also after 10 minutes of stimulation (34.0°C) (P = 0.01), there was found to be a significant increase in the skin temperature. The singular maximum value of 37.9°C bears a potential danger; however, compared to the local temperatures reached in transcutaneous blood gas measurements it appears not to entail any risks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes of Locoregional Skin Temperature in Neonates Undergoing Laser Needle Acupuncture at the Acupuncture Point Large Intestine 4

Laser acupuncture bears a potential risk for the skin surface, especially in neonates whose skin has histological and physiological peculiarities. We evaluated thermal changes of skin temperature in neonates during laser acupuncture by using a thermal camera (Flir i5, Flir Systems Inc., Portland, USA). Laserneedles (Laserneedle GmbH, Glienicke/Nordbahn, Germany) were fixed to the skin at Large ...

متن کامل

Near-Infrared Spectroscopy for Objectifying Cerebral Effects of Laser Acupuncture in Term and Preterm Neonates

Laser acupuncture (LA) becomes more and more relevant in neonates and infants. With near-infrared spectroscopy (NIRS), a continuous and noninvasive measurement of tissue oxygenation is possible. Aim was to investigate, whether the application of LA was associated with any changes in regional cerebral oxygen saturation (rcSO2) in term and preterm neonates. The study included 20 neonates (12 male...

متن کامل

High-Tech Acupuncture and Integrative Laser Medicine 2014

This is an annual special issue. The current issue is the 2013 issue which includes eleven interesting papers. Acupuncture has been used for medical treatment for thousands of years. A large number of empirical data is available, but the technical quantification of effects was not possible up to now. Using electroacupuncture, needle, or laser stimulation and modern biomedical techniques, it was...

متن کامل

Biomedical engineering meets acupuncture - development of a miniaturized 48-channel skin impedance measurement system for needle and laser acupuncture

BACKGROUND Due to controversially discussed results in scientific literature concerning changes of electrical skin impedance before and during acupuncture a new measurement system has been developed. METHODS The prototype measures and analyzes the electrical skin impedance computer-based and simultaneously in 48 channels within a 2.5×3.5 cm matrix. Preliminary measurements in one person were ...

متن کامل

The Efficacy of a Protocolized Nursing Care on Nasal Skin Breakdown in Preterm Neonates Receiving Nasal Continuous Positive Airway Pressure

Background: Nasal continuous positive airway pressure (NCPAP) is an effective method of ventilation in newborns with respiratory distress syndrome (RDS). Using an appropriate nasal skin care protocol is identical to prevention or reduction of nasal skin breakdown in those who receive NCPAP. This study aimed to investigate the effectiveness of an evidence-based clinical care protocol on nasal sk...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012