Evaluation of the dynamic conformal arc therapy in comparison to intensity‐modulated radiation therapy in prostate, brain, head‐and‐neck and spine tumors

نویسندگان

  • Manuel A. Morales‐Paliza
  • Charles W. Coffey
  • George X. Ding
چکیده

To evaluate dynamic conformal arc therapy (DAT) dose distribution and clinical applicability in comparison to intensity modulated radiotherapy (IMRT) in different types of tumors and locations, twelve patients with prostate cancer with no node involvement and three patients with single tumors in the pituitary, in the neck and in the thoracic spinal region treated with IMRT, were retrospectively planned with DAT using Eclipse (V8.1). The prostate cases were also planned with three-dimensional conformal radiation therapy (3DCRT). Dose distributions were evaluated through comparisons of dose-volumetric histograms and in-house IMRT protocol constraints, as well as validated via ion chamber array measurements. DAT plans for prostate showed a statistically comparable achievement of tumor conformity and dose sparing for bladder and rectum when compared to IMRT. Dose on femoral heads were similar to those achieved using 3DCRT. DAT could be planned with similar results to those obtained in IMRT for the dose constraints of the defined structures by using a 360° arc for the brain lesion and several arcs including noncoplanar ones for the head-and-neck and spinal tumors. Experimental validation of the calculated dose distributions via gamma analysis of composite distributions for DAT provided that more than 95% of the pixels satisfy the criteria 3 mm-3%, which was similar to that of IMRT. The average number of monitor units was approximately five times lower than IMRT. In conclusion, DAT is capable of providing conformal dose distributions to the targets accomplishing many of the IMRT dose constraints simultaneously. Experimental dose-validation accuracy, ease of planning and reduced treatment times make DAT both acceptable and attractive for clinical use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

متن کامل

Dose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer

Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2010