Comparison of Dissolved Gases in Mineral and Vegetable Insulating Oils under Typical Electrical and Thermal Faults
نویسندگان
چکیده
Dissolved gas analysis (DGA) is attracting greater and greater interest from researchers as a fault diagnostic tool for power transformers filled with vegetable insulating oils. This paper presents experimental results of dissolved gases in insulating oils under typical electrical and thermal faults in transformers. The tests covered three types of insulating oils, including two types of vegetable oil, which are camellia insulating oil, Envirotemp FR3, and a type of mineral insulating oil, to simulate thermal faults in oils from 90 ̋C to 800 ̋C and electrical faults including breakdown and partial discharges in oils. The experimental results reveal that the content and proportion of dissolved gases in different types of insulating oils under the same fault condition are different, especially under thermal faults due to the obvious differences of their chemical compositions. Four different classic diagnosis methods were applied: ratio method, graphic method, and Duval’s triangle and Duval’s pentagon method. These confirmed that the diagnosis methods developed for mineral oil were not fully appropriate for diagnosis of electrical and thermal faults in vegetable insulating oils and needs some modification. Therefore, some modification aiming at different types of vegetable oils based on Duval Triangle 3 were proposed in this paper and obtained a good diagnostic result. Furthermore, gas formation mechanisms of different types of vegetable insulating oils under thermal stress are interpreted by means of unimolecular pyrolysis simulation and reaction enthalpies calculation.
منابع مشابه
An Investigation on Vegetable Oils as Potential Insulating Liquid
While choosing insulating oil, characteristic features such as thermal cooling, endurance, efficiency and being environment-friendly should be considered. Mineral oils are referred as petroleum-based oil. In this study, vegetable oils investigated as an alternative insulating liquid to mineral oil. Dissipation factor, breakdown voltage, relative dielectric constant and resistivity changes with ...
متن کاملProperties of Mineral Insulating Oils in Service
The infrastructure of the electricity grid and super grid system in the hitherto industrialized world was to a large extent built up in the decades following World War II with a peak in investments around 1960-1980. This means that the flotilla of power transformers is now starting to reach projected lifetime of around 40 years. During the last couple of decades there has also been an ongoin...
متن کاملInfluence of Copper Particles on Breakdown Voltage and Frequency-Dependent Dielectric Property of Vegetable Insulating Oil
The insulating performance of oil is vulnerable to particles especially the conductive particles. This paper investigated the influence of copper particles of micrometer size on the breakdown strength and frequency-dependent properties of vegetable oil. The AC breakdown voltage of contaminated vegetable oil with copper particles of different numbers (ranging from 103 to 106) was measured. The f...
متن کاملInvestigation of the Usage of Palm Oils with the Aim of Insulation in High Voltage Power System Equipments
Original scientific paper Power system equipment have conventionally used mineral oil for insulation and cooling. The preferable alloy material has to be generated with good chemical and electrical features. However, recent case has indicated the shortcomings of these fluids where they have poor characteristics particularly at fire and flash point and most significantly poor dielectric malfunct...
متن کاملFailure Analysis of a Power Transformer Using Dissolved Gas Analysis – a Case Study
Reliable and continued performance of power Transformer is the key to profitable generation and transmission of electric power. Failure of a large power transformer not only results in the loss of very expensive equipment, but it can cause significant guarantied damage as well. Replacement of that transformer can take up to a year if the failure is not disastrous and can result in tremendous re...
متن کامل