Echocardiographic Assessment of Cardiac Function by Conventional and Speckle‐Tracking Echocardiography in Dogs with Patent Ductus Arteriosus
نویسندگان
چکیده
BACKGROUND Patent ductus arteriosus (PDA) is one of the most common congenital heart defects in dogs. Advanced echocardiographic techniques such as speckle-tracking echocardiography (STE) have not been extensively used to evaluate cardiac function in affected dogs. HYPOTHESIS Advanced echocardiographic techniques are more sensitive than standard echocardiographic techniques in analyzing systolic function in dogs with PDA. ANIMALS Forty-four client-owned dogs: 34 dogs with PDA (preoperative evaluation) and 10 healthy sex- and weight-matched controls. METHODS Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed, including conventional (end-diastolic volumes indexed to body surface area in B and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B and M-mode [ESVIB /M ], allometric scaling in diastole and systole [AlloD/S], pulmonary flow to systemic flow [Qp/Qs], ejection fraction [EF] and fractional shortening [FS]) and speckle-tracking echocardiography ([STE]: global longitudinal, radial and circumferential strain [S] and strain rate [SR]). RESULTS Dogs with PDA had significantly different EDVIB /M , ESVIB /M , AlloD/S, Qp/Qs and all STE-derived parameters (global longitudinal S and SR, global circumferential S and SR, global radial S and SR)compared to healthy dogs. No correlation was found between standard techniques (EDVIB /M , ESVIB /M , AlloD/S, Qp/Qs) and STE-derived parameters (global longitudinal, circumferential and radial S and SR). CONCLUSION AND CLINICAL IMPORTANCE Conventional parameters routinely used to assess systolic function (EF and FS) were not different between the groups; STE-derived parameters identified subtle changes in cardiac systolic function and contractility between the 2 groups of dogs. Based on these findings, STE may be a more appropriate tool to assess cardiac contractility in dogs with PDA.
منابع مشابه
Speckle‐Tracking Echocardiography in Dogs With Patent Ductus Arteriosus: Effect of Percutaneous Closure on Cardiac Mechanics
BACKGROUND Patent ductus arteriosus (PDA) is 1 of the most common congenital heart defects in dogs and percutaneous closure is effective in achieving ductal closure; PDA closure is associated with abrupt hemodynamic changes. HYPOTHESIS A marked decrease in standard parameters of systolic function as assessed by M- or B-mode echocardiography after PDA closure was identified in previous studies...
متن کاملEvaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)
The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...
متن کاملPatent ductus arteriosus in a lamb: A case report
Patent ductus arteriosus (PDA) is a persistent patency of a vessel normally present in the fetus that connects the pulmonary arterial system to the aorta. The ductus arteriosus fails to close at birth when breathing commences and placental blood circulation is removed. Closure of the ductus arteriosus arises in response to decline pulmonary vascular resistance and increased systemic vascular re...
متن کاملAnatomic, histopathologic, and echocardiographic features in a dog with an atypical pulmonary valve stenosis with a fibrous band of tissue and a patent ductus arteriosus
BACKGROUND Congenital pulmonary valve stenosis and patent ductus arteriosus are common congenital heart defects in dogs. However, concurrence of atypical pulmonary valve stenosis and patent ductus arteriosus is uncommon. This report describes the anatomic, histopathologic, and echocardiographic features in a dog with concomitant pulmonary valve stenosis and patent ductus arteriosus with atypica...
متن کاملEchocardiographic Evaluation of Myocardial Changes Observed After Closure of Patent Ductus Arteriosus in Dogs
BACKGROUND Closure of PDA can be associated with echocardiographic changes including deterioration of LV systolic function. Although PDA is commonly encountered in dogs, few comprehensive reports of echocardiographic changes in dogs with PDA closure are available. OBJECTIVES To evaluate the short-term echocardiographic changes observed after PDA closure in dogs using strain analysis. ANIMAL...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 30 شماره
صفحات -