Discrimination Calibration Analysis Methods for Regional Stations

نویسندگان

  • Dale N. Anderson
  • Deborah K Fagan
  • Steven R Taylor
  • Theresa M Mercier
چکیده

For event discrimination, operational implementation of a regional seismic station requires three sequential calibration analyses. 1) Magnitude, distance, and amplitude corrections (MDAC) made to observed regional amplitudes are necessary so that what remains in the corrected amplitude is mostly information about the seismic source-type. Corrected amplitudes can be used in ratios to discriminate between earthquakes and explosions. Calibration of MDAC can be accomplished with empirical Bayes estimation, which naturally provides metrics to determine when adequate calibration data have been acquired, and provides statistical assurance that the errors associated with MDAC calibration are negligible in future operational discrimination analysis. 2) MDAC-corrected amplitudes can then be used in ratios to discriminate between earthquakes and explosions. However, there remain source effects such as those due to depth, focal mechanism, local material property and apparent stress variability that cannot easily be determined and applied as amplitude corrections. We have developed a mathematical model to capture these near source effects as random (unknown) giving an error partition of three sources: model inadequacy, station noise and amplitude correlation. This mathematical model is the basis for a general multi-station regional discriminant. Calibration analysis for the standard error of the discriminant includes the calculation of the variances of model inadequacy and station noise, and amplitude correlation. 3) Likelihood-based seismic event identification analysis with MDAC discriminants requires estimated source population means and covariance matrices for the discriminants from each of the possible source types used in our analysis (e.g., deep earthquake, shallow earthquake, and explosion). Anderson et al. (2007) note that source population covariance matrices and the pooled covariance matrix are best estimated element-wise to fully utilize available calibration events. We propose an algorithm that may be used to mildly adjust an element-wise covariance matrix to ensure positive definiteness and non-singular behavior. The algorithm uses the Frobenius norm as the calibration metric because it minimally adjusts the variance terms of an element-wise covariance relative to the off-diagonal covariance terms to achieve a stable, positive semidefinite covariance matrix. Importantly, we show that it is not necessary to propagate the errors of MDAC parameter estimates to final event identification analysis. 2008 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Calibration and Discrimination in Northeast Russia

In an effort to obtain ground truth (GT) classifications in support of nuclear explosion monitoring for continental regions of northeastern Russia, we relocated and assigned GT classifications to 118 seismic events reported in the International Seismological Centre (ISC) supplemented with previously unavailable local data. Of the relocated events, 26 events are classified as GT10. From these ev...

متن کامل

Outcome prediction of different groups of patients using a modified scoring system

  Abstract   Background: In this study we aimed to examine the discrimination and calibration of   a severity characterization of trauma (ASCOT) in our setting to determine whether its usage   is appropriate to predict outcome of our trauma patients.   Methods: This study was conducted in three hospitals. All patients admitted in studied   hospitals were divided randomly into two equal subgroup...

متن کامل

Comparison of Single- site and Multi-site Based Calibrations of SWAT in Taleghan Watershed, Iran

Calibration of model is critical for hydrologic modeling of large watersheds in a mountain watershed. In this study Soil and Water Assessment Tool (SWAT) used to comparison a single-site calibration procedure that employed streamflow measurement at outlet of watershed to a multi-site calibration method that used streamflow measurements at three stations (Galinak, Joestan and Dehdar). Results sh...

متن کامل

Application of Regularized Discrimination Analysis to Regional Seismic Event Identification

We present a generalized multivariate seismic event identification method, Regularized Discrimination Analysis (RDA) [Friedman 1989], that can be applied to a large number of regional discriminants. RDA is readily adaptable to an outlier or classical identification approach to regional seismic identification. RDA is designed to address the problems associated with linear (LDA) and quadratic (QD...

متن کامل

Regional Validation and Recalibration of Clinical Predictive Models for Patients With Acute Heart Failure

BACKGROUND Heart failure clinical practice guidelines recommend applying validated clinical predictive models (CPMs) to support decision making. While CPMs are now widely available, the generalizability of heart failure CPMs is largely unknown. METHODS AND RESULTS We identified CPMs derived in North America that predict mortality for patients with acute heart failure and validated these model...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010