Left Ventricular Pacing in a Patient with a Mechanical Tricuspid Prosthesis and High Surgical Risk

نویسندگان

  • Sergio Conti
  • Claudio Liotta
  • Alfredo Virgilio
  • Corrado Tamburino
  • Valeria Calvi
چکیده

Transvenous endocardial pacemaker (PM) implantation is contraindicated in patients with a mechanical tricuspid prosthesis. These patients usually undergo epicardial lead implantation. This case shows the implant of left ventricular (LV) pacing lead through the coronary sinus (CS) in a patient with high surgical risk. A 77-year-old woman with slow atrial fibrillation, left anterior hemiblock and right bundle brunch block, who previously underwent surgical replacement of the mitral and tricuspid valves, was admitted for PM implantation. After 1 month, all the electric parameters were stable. To the best of our knowledge, this is the first Italian case reported of LV pacing in a patient with a mechanical tricuspid prosthesis. The use of LV pacing leads implanted through the CS provides a minimal invasive, safe and effective strategy of pacing in patients with a mechanical tricuspid prosthesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventricular Pacing via the Coronary Sinus in a Patient with a Mechanical Tricuspid Valve Prosthesis

Implantation of a transvenous endocardial pacing lead in the right ventricle is contraindicated after mechanical tricuspid valve replacement; therefore a surgical approach to the epicardium is usually required. This case report describes ventricular pacing via a branch of the coronary sinus in a patient with mechanical mitral, aortic and tricuspid valve replacements. In conclusion, this approac...

متن کامل

Transvenous right ventricular pacing in a patient with tricuspid mechanical prosthesis

We report a patient in whom permanent endocardial pacing was accomplished by passage of the electrode through a mechanical tricuspid valve. Echocardiography study showed a minimal tricuspid regurgitation.

متن کامل

Single site pacing through the anterior interventricular vein in a patient with a mechanic tricuspid valve

Transvenous endocardial pacing through classical implantation of a pace/sensing lead in the right ventricle is strictly contraindicated in patients with a mechanical tricuspid valve. Usually permanent pacing is achieved by an epimyocardial surgical approach. We hereby describe the implantation of a single site left ventricle pacing lead in the anterior interventricular vein in a 60 year-old wom...

متن کامل

Heart Carcinoid Disease with Patent Foramen Ovale Treated by Mini Sternotomy

This case report was an attempt to present the importance of diagnostic echocardiography and closure of a patent foramen ovale in carcinoid heart disease. Herein, we present a case of a 48-year-old woman with a carcinoid metastasis presenting with tricuspid regurgitation, pulmonic stenosis, patent foramen ovale, and borderline left ventricular ejection fraction on an echocardiogram. Surgical in...

متن کامل

RIght VErsus Left Apical transvenous pacing for bradycardia: Results of the RIVELA randomized study

AIMS To compare cardiac function when pacing from the right or left ventricular apex in patients with preserved left ventricular systolic function, at 1-year follow-up. METHODS Prospective, multicentre centre randomizing conventional right ventricular apical (RVA) versus left ventricular apical (LVA) pacing using a coronary sinus lead in patients requiring ventricular pacing for bradycardia. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014