Highly Cross-Linked Polyethylene in Total Hip and Knee Replacement: Spatial Distribution of Molecular Orientation and Shape Recovery Behavior

نویسندگان

  • Yasuhito Takahashi
  • Toshinori Masaoka
  • Giuseppe Pezzotti
  • Takaaki Shishido
  • Toshiyuki Tateiwa
  • Kosuke Kubo
  • Kengo Yamamoto
چکیده

The present study investigated effects of processing procedures on morphology of highly cross-linked and re-melted UHMWPE (XLPE) in total hip and knee arthroplasty (THA, TKA). The shape recovery behavior was also monitored via uniaxial compression test at room temperature after non-destructive characterizations of the in-depth microstructure by confocal/polarized Raman spectroscopy. The goal of this study was to relate the manufacturing-induced morphology to the in vivo micromechanical performance, and ultimately to explore an optimal structure in each alternative joint bearing. It was clearly confirmed that the investigated XLPE hip and knee implants, which were produced from different orthopaedic grade resins (GUR 1050 and GUR 1020), consisted of two structural regions in the as-received states: the near-surface transitional anisotropic layer (≈100 μm thickness) and the bulk isotropic structural region. These XLPEs exhibited a different crystalline anisotropy and molecular texture within the near-surface layers. In addition, the knee insert showed a slightly higher efficiency of shape recovery against the applied strain over the hip liner owing to a markedly higher percentage of the bulk amorphous phase with intermolecular cross-linking. The quantitative data presented in this study might contribute to construct manufacturing strategies for further rationalized structures as alternative bearings in THA and TKA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cross-linked Polyethylene Engineered for TKA

Introduction It is well known that the wear resistance of ultra-high molecular weight polyethylene (UHMWPE) improves in proportion to the crosslinking irradiation dose. It is also well known that the mechanical properties and oxidative stability of UHMWPE are affected by the irradiation dose, resin type, and post-irradiation heat treatment, among others factors. Therefore, careful consideration...

متن کامل

Notch Effects Under Physiologically-Relevant Conditions of Conventional and Highly Crosslinked UHMWPEs

Introduction: Ultra high molecular weight polyethylene (UHMWPE) components used in total joint replacements have rims and fillets that act as design stress risers; thus, it is of interest to determine the behavior UHMWPE under multiaxial loading conditions. Currently, there are a number of conventional and crosslinked UHMWPE formulations in clinical use in total hip and total knee replacement c...

متن کامل

Fracture of Two Moderately Cross-Linked Polyethylene Tibial Inserts in a TKR Patient

Highly cross-linked polyethylene has become the gold standard in total hip replacement for its wear resistance. Moderately crosslinked polyethylene is now available for total knee replacement (TKR), although concerns about reduced mechanical strength have prevented widespread adoption. The purpose of this report is to describe an unusual case where a patient underwent cruciate retaining TKR usi...

متن کامل

Knee Simulator Wear of Cross-linked Uhmwpe with Normal and Mal-rotation Kinematics

Introduction: Wear of ultra-high molecular weight polyethylene (UHMWPE) is a major factor that affects longevity of the total joint replacement. In total hips (THR), cross-linking of polyethylene has been shown to be highly effective in reducing wear both clinically and experimentally [1-3]. Also, in TKR, Schmidig et al. [4] showed a 90% reduction of wear rate in 10 Mrad compared to 3 Mrad tibi...

متن کامل

Reduction of Wear in Fixed Bearing Total Knee Replacement Using Crosslinked Uhmwpe

Introduction Reduction of ultra high molecular weight polyethylene (UHMWPE) surface wear in total knee replacement (TKR) bearings may delay the onset of osteolysis and subsequent loosening of components. Crosslinking has been shown to increase the wear resistance of UHMWPE bearings in multidirectional total hip replacement applications when articulating against smooth counterfaces [1]. The aim ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014