Hepatic arterial spin labelling MRI: an initial evaluation in mice
نویسندگان
چکیده
The development of strategies to combat hepatic disease and augment tissue regeneration has created a need for methods to assess regional liver function. Liver perfusion imaging has the potential to fulfil this need, across a range of hepatic diseases, alongside the assessment of therapeutic response. In this study, the feasibility of hepatic arterial spin labelling (HASL) was assessed for the first time in mice at 9.4 T, its variability and repeatability were evaluated, and it was applied to a model of colorectal liver metastasis. Data were acquired using flow-sensitive alternating inversion recovery-arterial spin labelling (FAIR-ASL) with a Look-Locker readout, and analysed using retrospective respiratory gating and a T1 -based quantification. This study shows that preclinical HASL is feasible and exhibits good repeatability and reproducibility. Mean estimated liver perfusion was 2.2 ± 0.8 mL/g/min (mean ± standard error, n = 10), which agrees well with previous measurements using invasive approaches. Estimates of the variation gave a within-session coefficient of variation (CVWS) of 7%, a between-session coefficient of variation (CVBS) of 9% and a between-animal coefficient of variation (CVA) of 15%. The within-session Bland-Altman repeatability coefficient (RCWS) was 18% and the between-session repeatability coefficient (RCBS) was 29%. Finally, the HASL method was applied to a mouse model of liver metastasis, in which significantly lower mean perfusion (1.1 ± 0.5 mL/g/min, n = 6) was measured within the tumours, as seen by fluorescence histology. These data indicate that precise and accurate liver perfusion estimates can be achieved using ASL techniques, and provide a platform for future studies investigating hepatic perfusion in mouse models of disease.
منابع مشابه
4D-MRA in combination with selective arterial spin labelling for functional characterization of arteriovenous malformations at 3 T
Introduction: Arteriovenous malformations (AVMs) account for an increasingly recognized cause of death and long-term morbidity due to there lifelong risk of bleeding. MRI of AVMs should answer two major questions: first Spetzler-Martin-classification, which determines surgical outcome and second correct identification of feeding arteries and anatomic variants. It has recently been shown that 4D...
متن کاملVascular assessment of liver disease—towards a new frontier in MRI
Complex haemodynamic phenomena underpin the pathophysiology of chronic liver disease. Non-invasive MRI-based assessment of hepatic vascular parameters therefore has the potential to yield meaningful biomarkers for chronic liver disease. In this review, we provide an overview of vascular sequelae of chronic liver disease amenable to imaging evaluation and describe the current supportive evidence...
متن کاملA novel use of arterial spin labelling MRI to demonstrate focal hypoperfusion in individuals with posterior cortical atrophy: a multimodal imaging study
INTRODUCTION Posterior cortical atrophy (PCA) is a rare neurodegenerative syndrome, typically due to Alzheimer pathology, characterised by impairments in higher-order visual function and other parieto-occipital skills. MRI measures of atrophy and F-labelled fluorodeoxyglucose (FDG) positron emission tomography (PET) measures of glucose metabolism typically show posterior cortical deficits broad...
متن کاملPerfusion MRI: Non-Linear Stochastic Regularization for Deconvolution of Model-Free Arterial Spin Labelling Data
متن کامل
Patterns of postictal cerebral perfusion in idiopathic generalized epilepsy: a multi-delay multi-parametric arterial spin labelling perfusion MRI study
The cerebral haemodynamic status of idiopathic generalized epilepsy (IGE) is a very complicated process. Little attention has been paid to cerebral blood flow (CBF) alterations in IGE detected by arterial spin labelling (ASL) perfusion magnetic resonance imaging (MRI). However, the selection of an optimal delay time is difficult for single-delay ASL. Multi-delay multi-parametric ASL perfusion M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 28 شماره
صفحات -