High-resolution imaging 1D and 2D solid-state detector systems
نویسندگان
چکیده
We have developed high energy and high spatial resolution 1D and 2D solid state imaging detectors and their custom integrated circuits (ICs). Readout ICs are now regarded to be an integral part of position-sensitive semiconductor detectors, especially for Si and CdZnTe for x-ray and gamma-ray imaging. These detectors have a 1D or 2D structure. The 1D structure types are mostly used for scanning purposes with some staring type imaging while 2D pixel detectors can be used for both scanning and staring mode imaging applications. Because the requirements of various detector applications tend to be diverse, a custom IC is typically designed for a specific detector array. This often lengthens the time and raises the cost of system development. To help close the readout technology gap and facilitate advances in this field, we have been formulating and implementing strategies for instrumenting different detectors of a given application category with highly versatile ICs that meet a range of requirements. The solid-state detectors and their ICs that have been developed within this effort are presented.
منابع مشابه
Electro-Optical Design of Imaging Payload for a Remote Sensing Satellite
Remote sensing using small spacecraft arising from multi-objective economic activity problems is getting more and more developed. These satellites require very accurate pointing to specific locations of interest, with high reliability and small latency. The space borne imaging systems always attempted to achieve the highest ground resolution possible with the available technology at the given t...
متن کاملOptimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system
Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...
متن کاملA Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region
Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...
متن کاملInvestigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code
Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...
متن کاملOne-dimensional Spectroscopic Measurement of Patterned Structures Using a Custom-built Spectral Imaging Ellipsometer
A novel spectral imaging ellipsometer based on a mono-axial power spectrograph has been developed for one-dimensional spectroscopic measurement of patterned structures. To obtain the imaging data of a patterned sample using ellipsometry can be realized by conventional ellipsometers with 2-dimesional (2D) scanning sample stage or 2D imaging ellipsometers with imaging optics. The former has major...
متن کامل