A circumferentially flanged tibial tray minimizes bone-tray shear micromotion.

نویسندگان

  • D S Barker
  • K E Tanner
  • L Ryd
چکیده

Aseptic loosening of the tibial component is the major complication of total knee arthroplasty. There is an association between early excessive shear micromotion between the bone and the tray of the tibial component and late aseptic loosening. Using non-linear finite element analysis, whether a tibial tray with a circumferentially flanged rim and a mating cut in the proximal tibia could minimize bone-tray shear micromotion was considered. Fifteen competing tray designs with various degrees of flange curvature were assessed with the aim of minimizing bone-tray shear micromotion. A trade-off was found between reducing micromotion and increasing peripheral cancellous bone stresses. It was found that, within the limitations of the study, there was a theoretical design that could virtually eliminate micromotion due to axial loads, with minimal bone removal and without the use of screws or pegs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micromotion at the tibial plateau in primary and revision total knee arthroplasty: fixed versus rotating platform designs.

OBJECTIVES Initial stability of tibial trays is crucial for long-term success of total knee arthroplasty (TKA) in both primary and revision settings. Rotating platform (RP) designs reduce torque transfer at the tibiofemoral interface. We asked if this reduced torque transfer in RP designs resulted in subsequently reduced micromotion at the cemented fixation interface between the prosthesis comp...

متن کامل

Effect of Tibial Tray Malalignment on Micromotion and Subsidence: A Preliminary Report

Malalignment of the tibial tray in total knee arthroplasty has been linked to several complications including tibial tray subsidence, leading to revision surgery. However, quantitative biomechanical evidence to directly support the mechanism of failure is not available. We developed a model to study tibial tray micromotion and subsidence in vitro under multiaxial physiological loading condition...

متن کامل

Patient-Specific Unicompartmental Knee Resurfacing Arthroplasty: Use of a Novel Interference Lock to Reduce Tibial Insert Micromotion and Backside Wear

Micromotion has long been associated with wear of polyethylene tibial inserts, potentially causing failure of unicompartmental knee replacement systems. One cause of micromotion is the locking mechanism between the undersurface of the polyethylene and the tibial tray. The objective of this study was to investigate the use of new novel lock designs for reducing the micromotion associated with a ...

متن کامل

Influence of Alignment on the Primary Stability of Cementless Tibial Trays: A Combined KneeSim and Finite Element Study

INTRODUCTION: Cementless tibial fixation has been used for over 30 years. There are several potential advantages including preservation of bone stock and ease of revision [1]. More importantly, particularly for younger, more active patients, there is the potential for increased longevity of the fixation. However, the clinical results with cementless fixation have been variable, with reports of ...

متن کامل

Comparison of tibial bone coverage of 6 knee prostheses: a magnetic resonance imaging study with controlled rotation.

PURPOSE To compare the extent of tibial bone covered by the tibial tray in 6 most commonly used total knee arthroplasty designs in order to strike a balance between mediolateral cortical fit and optimal tibial component rotation. METHODS In 74 men and 27 women aged 17 to 60 (mean, 32) years with suspected soft-tissue injuries, their magnetic resonance images of the knee in full extension were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 219 6  شماره 

صفحات  -

تاریخ انتشار 2005