Headform and N95 filtering facepiece respirator interaction: contact pressure simulation and validation.

نویسندگان

  • Zhipeng Lei
  • Jingzhou James Yang
  • Ziqing Zhuang
چکیده

This article presents a computational and experimental study of contact pressure between six N95 filtering facepiece respirators (FFRs) and five newly developed digital headforms (small, medium, large, long/narrow, and short/wide). Contact interaction is simulated using the finite element method and validated by experiments using a pressure mapping system. The headform model has multiple layers: a skin layer, muscle layer, fatty tissue layer, and bone layer. Each headform is divided into five parts (two parts for the cheeks, one part for the upper forehead, one part for the chin, and one part for the back side of the head). Each respirator model comprises multiple layers and two straps. The simulation process has two stages for each respirator/headform combination. The first stage is to wrap the straps around the back of the headform and pull the respirator away from the face. The second stage is to release the respirator so that the respirator moves toward the face. Strap forces and contact interactions are generated between the respirators and the headforms. Meanwhile, a real-time surface pressure mapping system is used to record the pressures at six key locations to validate the computational results. There is a strong correlation between computational and experimental results (R(2) = 0.88). By comparing the pressure values from simulations and experiments, we have validated the simulation models.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulated effects of head movement on contact pressures between headforms and N95 filtering facepiece respirators part 2: simulation.

Finite element (FE) filtering facepiece respirators (FFRs) were developed and mated to the new headforms with a cervical spine model. The FFRs from three manufacturers included three sizing systems: (i) a single one-size-fits all, (ii) an FFR with two sizes (S/M and M/L), and (iii) an FFR with three sizes (S, L/M, XL). Finite element method (FEM) simulations of 16 headform and respirator combin...

متن کامل

Correlation of respirator fit measured on human subjects and a static advanced headform.

This study assessed the correlation of N95 filtering facepiece respirator (FFR) fit between a Static Advanced Headform (StAH) and 10 human test subjects. Quantitative fit evaluations were performed on test subjects who made three visits to the laboratory. On each visit, one fit evaluation was performed on eight different FFRs of various model/size variations. Additionally, subject breathing pat...

متن کامل

Effect of surgical masks worn concurrently over N95 filtering facepiece respirators: extended service life versus increased user burden.

Growing concern over the availability of Respiratory protective devices (eg, filtering facepiece Respirators), in the face of the probable extreme demand brought on by a pandemic influenza, has prompted the suggestion that useful life of N95 filtering facepiece Respirator can be extended by the concurrent use of a surgical mask as an outer protective barrier over the Respirator. Personal protec...

متن کامل

Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators.

A method for performing quantitative fit tests (QNFT) with N95 filtering facepiece respirators was developed by earlier investigators. The method employs a simple clamping device to allow the penetration of submicron aerosols through N95 filter media to be measured. The measured value is subtracted from total penetration, with the assumption that the remaining penetration represents faceseal le...

متن کامل

Evaluation of the Filtration Efficiency of the N95 Filtering Facepiece Respirator for Airborne Methicillin-Resistant Staphylococcus aureus

Airborne methicillin-resistant Staphylococcus aureus (MRSA) was detected inside a swine facility that presented a risk of respiratory colonization and infection to swine and swine workers. Viable airborne MRSA was sampled using an Andersen cascade impactor, and total airborne particulates were sampled using an optical particle counter. The filter efficiency of the N95 filtering facepiece respir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of occupational and environmental hygiene

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2012