Dual Control High-rise Building for Robuster Earthquake Performance
نویسندگان
چکیده
A dual passive control system is proposed for high-rise buildings. Since the proposed system needs a substructure supporting the main building, it is usually used in high-rise residential apartment houses where a parking tower is used as the substructure. This new system consists of a base-isolation system and a building-connection system. While base-isolated buildings and interconnected buildings are effective for special earthquake ground motions, i.e., impulsive type and long-duration type, respectively, a building structure with such system as robust for both type inputs has never been proposed and investigated in detail. Although some attempts have been conducted, realization of such systems has never been accomplished. In this paper, not only the theoretical background but also the actual installation in a real world is presented in detail. It is shown that the transfer function of the proposed dual building control system possesses lower values in a broader frequency range compared to the conventional building-connection system. This supports the high robustness of the proposed dual building system. It is also shown that the optimal connecting damper quantity providing a lower response of the main frame can be obtained by maximizing the area of energy transfer function which implies the energy absorption of the connecting dampers under an idealized white noise-like input.
منابع مشابه
OPTIMUM LAYOUT OF NONLINEAR FLUID VISCOUS DAMPER FOR IMPROVEMENT THE RESPONSES OF TALL BUILDINGS
The utilization of passive energy dissipation systems has been created a revolution in the structural engineering industry due to their advantages. Fluid Viscous Damper (FVD) is one of these control systems. It has been used in many different industries, such as the army, aerospace, bridge, and building structures. One of the essential questions about this system is how it can combine with the ...
متن کاملTuned Mass Dampers for Earthquake Vibrations of High-rise Buildings using Bee Colony Optimization Technique
This paper investigates the application of Artificial Bee Colony (ABC) method for the optimization of Tuned Mass Dampers (TMDs) employed for high-rise structures including Soil Structure Interaction (SSI). The model is a 40-story building, and Newmark method is utilized for the structure response to Bam earthquake data. The objective is to decrease both maximum displacement and accelerati...
متن کاملOPTIMIZED TUNED LIQUID COLUMN DAMPERS FOR EARTHQUAKE OSCILLATIONS OF HIGH-RISE STRUCTURES INCLUDING SOIL EFFECTS
This paper investigates the optimized parameters for the tuned liquid column dampers to decrease the earthquake vibrations of high-rise buildings. Considering soil effects, the soilstructure interaction (SSI) is involved in this model. The Tuned Liquid Column Damper (TLCD) is also utilized on the roof of the building. Since the TLCD is a nonlinear device, the time domain analysis based on nonli...
متن کاملRanking Passive Seismic Control Systems by Their Effectiveness in Reducing Responses of High-Rise Buildings with Concrete Shear Walls Using Multiple-Criteria Decision Making
In recent decades, the dual systems of steel moment-resisting frames and RC shear walls have found extensive application as lateral load-resisting systems for high-rise structures in seismically active areas. This paper investigated the effectiveness of tuned mass damper (TMD), viscous damper, friction damper, and the lead-core rubber bearing in controlling the damage and seismic response of hi...
متن کاملEstimating the inter-story drift in high rise buildings with the flexural and shear cantilever beam and mode-acceleration method
In this study, the seismic inter-story drift of structures is estimated by a combination of mode-acceleration equations with the modelling of high-rise buildings with flexural and shear cantilever beams. In the equation presented for calculating the inter-story drift, having less knowledge of the building is adequate and this issue is of significance in estimating the nonstructural component fo...
متن کامل