Whole-Body Low-Dose Computed Tomography (WBLDCT) in Assessment of Patients with Multiple Myeloma – Pilot Study and Standard Imaging Protocol Suggestion

نویسندگان

  • Robert Chrzan
  • Artur Jurczyszyn
  • Andrzej Urbanik
چکیده

BACKGROUND For decades, the main imaging tool in multiple myeloma (MM) patients was plain radiography. However, computed tomography (CT) has been included in the updated criteria of MM. The main disadvantage of CT is a considerably high radiation dose. Therefore, low-dose CT protocols could be a solution. The aim of the study was to (1) preliminarily analyse the usefulness of Whole-Body Low-Dose CT (WBLDCT) in the evaluation of patients with MM and (2) to make adjustments in the standard CT imaging protocol. MATERIAL/METHODS In 41 patients with MM, WBLDCT was performed. The following parameters were used: detector configuration - 80×0.5 mm, scanning range in a single spiral acquisition from the skull to the proximal femoral bones, tube voltage - 120 kVp, current tube time product - 86 mAs, slice thickness 1 mm. Two sets of axial images were reconstructed for bone and soft tissue assessment, respectively. Secondary coronal and sagittal reconstructions were generated. Typical MM features were analysed and qualitatively compared with radiography results. RESULTS A potentially increased sensitivity of CT, as compared to radiography, in detecting lytic foci obscured by other structures or with a small degree of destruction was seen. A potentially increased specificity of CT was found in detecting cases of small foci suspicious of lytic lesions on skull radiographs, seen as arachnoid granulations fovea in CT. The following radiation parameters were recorded: max. CTDIvol - 7.4 mGy and DLP - 660-810 mGy×cm. WBLDCT was much shorter and more convenient to patients. CONCLUSIONS WBLDCT may become a valuable part of the assessment of MM features at a much lower radiation dose compared to standard CT protocols. It has a potential ability to increase diagnostic accuracy compared to radiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Whole-body low-dose computed tomography and advanced imaging techniques for multiple myeloma bone disease.

Detection of lytic bone lesions is crucial in the workup for multiple myeloma and very often dictates the decision to start treatment. Conventional radiography, despite decades of use, is often insufficient for detection of bone disease in multiple myeloma. Modern imaging techniques such as MRI, PET, and CT offer superior detection of myeloma bone disease and extramedullary manifestations of pl...

متن کامل

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

Body fat composition as predictive factor for treatment response in patients with newly diagnosed multiple myeloma – subgroup analysis of the prospective GMMG MM5 trial

INTRODUCTION/BACKGROUND Obesity is a well-known risk factor for malignant tumors and increased body mass index (BMI) is correlated to the risk of developing multiple myeloma (MM). The correlation of body fat composition with disease activity, adverse events and treatment response of MM patients has not been investigated yet. PATIENTS AND METHODS A subgroup of 108 patients from a single instit...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2017