Constructing quasi-linear V̇O2 responses from nonlinear parameters.

نویسندگان

  • Samuel L Wilcox
  • Ryan M Broxterman
  • Thomas J Barstow
چکیده

Oxygen uptake (V̇O2) kinetics have been shown to be governed by a nonlinear control system across a range of work rates. However, the linearity of the V̇O2 response to ramp incremental exercise would appear to be the result of a linear control system. This apparent contradiction could represent a balancing of changing V̇O2 kinetics parameter values across a range of work rates. To test this, six healthy men completed bouts of ramp incremental exercise at 15, 30, and 60 W/min (15R, 30R, 60R, respectively) and four bouts of an extended-step incremental exercise. V̇O2 parameter values were derived from the step exercise using two monoexponential models: one starting at time zero and encompassing the entire stage (MONO), and the other truncated to the first 5 min and allowing a time delay (5TD). The resulting parameter values were applied to an integrative model to estimate the ramp responses. As work rate increased, gain values increased (P < 0.001 for MONO and 5TD), as did mean response time (or time constant) values (MONO: P < 0.001; 5TD: P = 0.003). Up to maximal V̇O2 (V̇O(2 max)), the gains of the estimated ramp responses from both models were not different from the gains of the actual observed V̇O2 responses for 15R and 30R (15R: 11.3 ± 1.2, 11.7 ± 0.7, 10.9 ± 0.3; 30R: 10.5 ± 0.8, 11.0 ± 0.5, 10.7 ± 0.3 ml O2·min(-1)·W(-1), for actual, MONO, 5TD, respectively) but were significantly greater for 60R (8.7 ± 1.0, 9.9 ± 0.4, 10.3 ± 0.3 ml O2·min(-1)·W(-1) for actual, MONO, 5TD, respectively). Up to 80%V̇O(2 max) gain values were not significantly different for any ramp rate (P > 0.05 for all). We conclude that the apparent linearity of the V̇O2 response to ramp incremental exercise is consequent to a balancing of increasing time constant and gain parameter values.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Linear VO2 Response from Non-Linear Parameters

Constructing quasi-linear VO2 responses from nonlinear parameters 1 JAPPL-00507-2015R2 2 3 Wilcox, Samuel L.1, Broxterman, Ryan M.2, Barstow, Thomas J.1 4 5 6 1 Department of Kinesiology, Kansas State University, Manhattan, KS, U.S.A. 7 2 Department of Anatomy and Physiology, Kansas State University, Manhattan, KS, U.S.A. 8 9 Wilcox: Conceptualization, data collection and processing, and writin...

متن کامل

Responses of a two degree-of-freedom system coupled to a nonlinear damper under multi-forcing frequencies

In this paper, forced responses are investigated in a two degree-of-freedom linear system with a linear coupling to a Nonlinear Energy Sink (NES) subjected to quasi-periodic excitation. The quasi-periodic regimes associated to quasi-periodic forcing in the regime of 1:1-1:1 are studied analytically using the complexification method combined to the averaging method in terms of multi-time paramet...

متن کامل

Study on Identification of Nonlinear Systems Using Quasi-ARX Models

System identification can be used to construct a model to represent a given system, and it plays an important role in system analysis, control and prediction. From the view of application, conventional nonlinear black-box models are not good since an easy-to-use model is to interpret properties of the nonlinear process, rather than treated as vehicles for adjusting the fit to the data. Therefor...

متن کامل

Validity of Quasi-Linear Transport Model

In order to gain reliable predictions on turbulent fluxes in tokamak plasmas, physics based transport models have to be improved. On a confinement time scale, nonlinear gyrokinetic electromagnetic simulations for all species are still too costly in terms of computing time. On the other hand, interestingly, quasi-linear approximation seems to retain the relevant physics for fairly reproducing bo...

متن کامل

In-silico prediction of Cellular Responses to Polymeric Biomaterials from Their Molecular Descriptors

In this work quantitative structure activity relationship (QSAR) methodology was applied for modeling and prediction of cellular response to polymers that have been designed for tissue engineering. After calculation and screening of molecular descriptors, linear and nonlinear models were developed by using multiple linear regressions (MLR) and artificial neural network (ANN) methods. The root m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 120 2  شماره 

صفحات  -

تاریخ انتشار 2016