Comparison of capillary gas chromatographic method and automated spectrophotofluorometric methods for measuring content uniformity of conjugated oestrogens in pharmaceutical preparations

نویسندگان

  • J. D. Russell
  • J. Mumley
  • M. Spring
  • A. Kutz
  • R. N. Johnson
چکیده

To measure the content uniformity of conjugated cestrogens tablets, the USP XXII monograph specifies a capillary gas chromatographic method. This involves separation of the trimethylsilyl derivatives of the various oestrogens found in a typical conjugated oestrogens tablet using a fused-silica 0V 225 bonded phase column. Hydrogen is used as the carrier gas with FID detection. A more rapid spectrophotofluorometric method of analysis has been developed in which the oestrogens are extracted from the dosage form into water, then transferred into organic solvent as the dicyclohexylamine complex. Fluorescence is developed by heating the solution of the complex in the presence of 70% sulphuric acid. The chemistry and detection are carried out using a segmented-flow analyser.The spectrophotofluorometric method is preferred as a routine control for content uniformity because considerable time is saved during sample preparation and analysis compared to gas chromatography. Coefficients of variation show that both methods produce acceptable results. These results fall well within the USP XXII [1] monograph, limits and also well within the tighter limits imposed by the USP XXII, section 905.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

Comparison of Two Spectrophotometric Methods for Quantifying Total Hydroxycinnamic Acids in Coneflower (Echinacea purpurea) Preparations

Background & Aim: Hydroxycinnamic acids are one of the most important bioactive substances of Echinacea drugs. These compounds possess immuno-enhancing activity and thus, total hydroxycinnamic acids are mostly used as the main criterion for quality control of Echinacea purpurea and its drugs.  Hence, the quality control of Echinacea requires to develo...

متن کامل

An Improved GC Method for Rapid Analysis of Valproic Acid in Human Plasma Without Derivatization

        A simple, reproducible and rapid gas chromatographic method for precise determination of valproic acid (VPA) in human plasma has been developed. Total time for sample preparation and GC analysis is less than 45 min. After plasma protein precipitation, VPA was extracted into chloroform with suitable recovery. By using Stabilwax®<span styl...

متن کامل

Development and Validation of a Gc-fid Assay for Determination of Fluvastatin in Pharmaceutical Preparations

A gas chromatographic method has been developed for the assay of fluvastatin sodium (FLU). FLU was silylated with N,Obis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 90 oC for 30 min and analysed in a DB-1 column by capillary gas chromatograph with a flame ionization detector. The method was validated. The assay was linear over the concentration range at 10.0 to 50.0 mg mL. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 13  شماره 

صفحات  -

تاریخ انتشار 1991