Correction: Higuchi Dimension of Digital Images
ثبت نشده
چکیده
In equation 4, the two brackets surrounding [N-m/d] should be replaced by floor function brackets. Please view the correct equation here.
منابع مشابه
Higuchi Dimension of Digital Images
There exist several methods for calculating the fractal dimension of objects represented as 2D digital images. For example, Box counting, Minkowski dilation or Fourier analysis can be employed. However, there appear to be some limitations. It is not possible to calculate only the fractal dimension of an irregular region of interest in an image or to perform the calculations in a particular dire...
متن کاملInfluences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom
Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...
متن کاملSteganography Scheme Based on Reed-Muller Code with Improving Payload and Ability to Retrieval of Destroyed Data for Digital Images
In this paper, a new steganography scheme with high embedding payload and good visual quality is presented. Before embedding process, secret information is encoded as block using Reed-Muller error correction code. After data encoding and embedding into the low-order bits of host image, modulus function is used to increase visual quality of stego image. Since the proposed method is able to embed...
متن کاملImage quality enhancement in digital panoramic radiograph
One of the most common positioning errors in panoramic radiography is palatoglossal air space above the apices of the root of maxillary teeth. It causes a radiolucency obscuring the apices of maxillary teeth. In the case of this positioning error, the imaging should be repeated. This causes the patient be exposed to radiation again. To avoid the repetition of exposing harmful X-rays to the pati...
متن کاملOptimal fast digital error correction method of pipelined analog to digital converter with DLMS algorithm
In this paper, convergence rate of digital error correction algorithm in correction of capacitor mismatch error and finite and nonlinear gain of Op-Amp has increased significantly by the use of DLMS, an evolutionary search algorithm. To this end, a 16-bit pipelined analog to digital converter was modeled. The obtained digital model is a FIR filter with 16 adjustable weights. To adjust weights o...
متن کامل