Functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis

نویسندگان

  • David M. Spranz
  • Hendrik Bruttel
  • Sebastian I. Wolf
  • Felix Zeifang
  • Michael W. Maier
چکیده

BACKGROUND The aim of this study is to compare the functional midterm outcome of stemless shoulder prostheses with standard anatomical stemmed shoulder prostheses and to show that the STEMLESS results are comparable to the STEMMED with respect to active maximum range of shoulder motion (ROM) and Constant score (CS). METHODS Seventeen patients underwent total shoulder arthroplasty (TSA) in 25 shoulder joints. Stemless TSA was performed in 12 shoulder joints (group STEMLESS), third-generation stemmed TSA in 13 shoulder joints (group STEMMED). Functional results were documented using the CS. 3D-motion-analysis using the Heidelberg upper extremity model (HUX) was conducted to measure active maximum (ROM). RESULTS The group STEMLESS achieved a CS of 67.9 (SD 12.0) points and the group STEMMED of 70.2 (SD 5.8 points) without significant difference between the groups (p = 0.925). The maximum ROM of the group STEMLESS, ascertained by 3-D-motion-analysis, was in forward flexion 125.5° (SD 17.2°), in extension 49.4° (SD 13.8°), in abduction 126.2° (SD 28.5°) and in external rotation 40.3° (SD 13.9°). The maximum ROM of the group STEMMED, also ascertained by 3-D-motion analysis, was in forward flexion 135.0° (SD 16.8°), in extension 47.2° (SD 11.5°), in abduction 136.3° (SD 24.2°) and in external rotation 40.1° (SD 12.2°). The maximum ROM of the STEMLESS group was lower in forward flexion and abduction, higher in extension and almost identical in external rotation. But there was no significant difference (forward flexion p = 0.174, extension p = 0.470, abduction p = 0.345, external rotation p = 0.978). CONCLUSION Both types of shoulder prostheses achieve a similar and good active ROM and similar results in CS. TRIAL REGISTRATION DRKS00013166 , retrospectively registered, 11.10.2017.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are there differences between stemless and conventional stemmed shoulder prostheses in the treatment of glenohumeral osteoarthritis?

BACKGROUND Conventional stemmed anatomical shoulder prostheses are widely used in the treatment of glenohumeral osteoarthritis. The stemless shoulder prosthesis, in contrast, is a new concept, and fewer outcome studies are available. Therefore, the purpose of the study was to investigate the early functional outcome and postoperative proprioception of a stemless prosthesis in comparison with a ...

متن کامل

Radiological changes do not influence clinical mid-term outcome in stemless humeral head replacements with hollow screw fixation: a prospective radiological and clinical evaluation

BACKGROUND Stemless shoulder arthroplasty is a fairly new concept. Clinical and radiological follow-up is essential to prove implant safety and concept. This prospective single-centre study was performed to evaluate the influence of radiological changes on clinical mid-term outcome following stemless humeral head replacement with hollow screw fixation. METHODS Short- and mid-term radiological...

متن کامل

Is the stemless humeral head replacement clinically and radiographically a secure equivalent to standard stem humeral head replacement in the long-term follow-up? A prospective randomized trial.

BACKGROUND Stemless humeral head replacement represents a young generation of shoulder arthroplasty. This study evaluated the differences of this new stemless design compared with the fourth-generation standard stemmed design. METHODS Total shoulder arthroplasty was performed in 20 patients with a stemless shoulder prosthesis (group 1) and in 20 patients with a standard stem humeral head repl...

متن کامل

Nine-year outcome after anatomic stemless shoulder prosthesis: clinical and radiologic results.

BACKGROUND Several stemless shoulder implants are available on the market, but only a few studies have presented results with sufficient mid- to long-term follow-up. The present study evaluated clinical and radiologic outcomes 9 years after anatomic stemless shoulder replacement. METHODS This is a prospective cohort study evaluating the stemless shoulder prosthesis since 2005. Anatomic stemle...

متن کامل

Humeral bone grafting in stemless shoulder arthroplasty

Stemless shoulder arthroplasty with metaphyseal fixation of the humeral component is increasingly used in the treatment of primary or secondary osteoarthritis, achieving significant pain relief and improving both range of motion and patient satisfaction [1, 4, 6]. The majoradvantagesof the stemlesshumeral design are preservation of humeral bone stock, anatomical reconstruction regardless of hum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017