Age-Related Changes in Corneal Deformation Dynamics Utilizing Scheimpflug Imaging

نویسندگان

  • Marta E. Rogowska
  • D. Robert Iskander
  • Ted S Acott
چکیده

PURPOSE To study age-related changes in corneal deformation response to air-puff applanation tonometry. METHODS Fifty healthy subjects were recruited for a prospective study and divided into two equal age groups (≤ 28 and ≥ 50 years old). Up to three measurements by a corneal deformation analyser based on the Scheimpflug principle were performed on the left eye of each subject. Raw Scheimpflug images were used to extract changes in anterior and posterior corneal profiles, which were further modelled by an orthogonal series of Chebyshev polynomial functions. Time series of the polynomial coefficients of even order exhibited a dynamic behavior in which three distinct stages were recognized. A bilinear function was used to model the first and the third stage of corneal dynamics. Slope parameters of the bilinear fit were then tested between the two age groups using Wilcoxon rank sum test and two-way non-parametric ANOVA (Friedman) test. RESULTS Statistically significant changes (Wilcoxon test, P<0.05) between the age groups were observed in the phase of the second applanation dynamics for the posterior corneal profile. In a two-way comparison, in which the corneal profile was used as a dependent variable, statistically significant changes (ANOVA/Friedman test, P = 0.017) between the groups were also observed for that phase. CONCLUSION Corneal biomechanics depend on age. The changes in corneal deformation dynamics, which correspond to mostly free return of the cornea to its original shape after the air pulse, indicate that the age related differences in corneal biomechanics are subtle but observable with high speed imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors Associated With Corneal Deformation Responses Measured With a Dynamic Scheimpflug Analyzer.

Purpose The purpose of this study was to clarify correlations between corneal deformation parameters measured with a dynamic Scheimpflug analyzer and baseline factors such as axial length, intraocular pressure (IOP), age, central corneal thickness (CCT), and corneal curvature. Methods Ninety-six eyes of 96 healthy subjects (mean 55.2 ± 16.1 years of age) were examined using a dynamic Scheimpf...

متن کامل

Impact of chamber pressure and material properties on the deformation response of corneal models measured by dynamic ultra-high-speed Scheimpflug imaging.

PURPOSE To study the deformation response of three distinct contact lenses with known structures, which served as corneal models, under different chamber pressures using ultra-high-speed (UHS) Scheimpflug imaging. METHODS Three hydrophilic contact lenses were mounted on a sealed water chamber with precisely adjustable pressure: TAN-G5X (41% hydroxyethylmethacrylate/glycolmethacrylate, 550 µm ...

متن کامل

Analysis of the Viscoelastic Properties of the Human Cornea Using Scheimpflug Imaging in Inflation Experiment of Eye Globes

PURPOSE To demonstrate a Scheimpflug-based imaging procedure for investigating the depth- and time-dependent strain response of the human cornea to inflation testing of whole eye globes. METHODS Six specimens, three of which with intact corneal epithelium, were mounted in a customized apparatus within a humidity and temperature-monitored wet chamber. Each specimen was subjected to two mechani...

متن کامل

Longitudinal Evaluation of Cornea With Swept-Source Optical Coherence Tomography and Scheimpflug Imaging Before and After Lasik

Swept-source optical coherence tomography (OCT) is the latest advancement in anterior segment imaging. There are limited data regarding its performance after laser in situ keratomileusis (LASIK). We compared the reliability of swept-source OCT and Scheimpflug imaging for evaluation of corneal parameters in refractive surgery candidates with myopia or myopic astigmatism. Three consecutive measur...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015