Plasma amino-acid determinations by reversed-phase HPLC: Improvement of the orthophthalaldehyde method and comparison with ion exchange chromatography
نویسندگان
چکیده
Reversed-phase high performance liquid chromatographic (RPHPLC) determination of amino-acids with on-line pre-column ortho-phthalaldehyde (OPA) derivatization and fluorescence detection is rapid and sensitive. However, high-performance ionexchange chromatography (HP-IEC) with post-column ninhydrine reaction is the most widely used amino-acid (AA) assay for biological samples. These two methods have been compared for the determination of individual plasma AA concentrations.An excellent correlation (p </= 0.003) was found between the results given by an RP-HPLC system (Varian) and a classical AA autoanalyser (Biotronik LC 5001). Most AA concentrations were similar with the two methods, but a paired t-test showed slight differences for 13 AA. The within-batch reproducibility of the RPHPLC method was comparable to that of the HP-IEC method. The analysis was about three times faster with RP-HPLC, and sensitivity was l00-fold better. However, aspartic acid, proline and cysteine were not identified by the RP-HPLC method, while the tryptophan quantification is possible.RP-HPLC with automated pre-column OPA derivatization is clearly a suitable alternative for assaying physiological AA and may be particularly useful for AA present at low concentrations (free tryptophan, plasma 3-methylhistidine).
منابع مشابه
Immunoglobulin A Preparation from Human Pooled Plasma Using Plasma Fractionation and Ion Exchange Chromatography
Background: In this study we have prepared the IgA solution from normal human plasma using plasma fractionation and ion exchange chromatography. Materials and Methods: Using fractionation of plasma with cold ethanol (starting with 8% ethanol), fraction III was prepared as a suitable source for IgA preparation. Then it was treated with caprylic acid for separation of impurities. For enrichm...
متن کاملIsolation and purification of albumin from human plasma by direct and combined approach of ion-exchange chromatography and comparison of the final products quality obtained by both methods
Background: Due to multiple roles of albumin in the body, injection of its medicinal product as one of the therapeutic or management strategies under conditions such as severe bleeding, burns, liver failure, and neonatal hemolytic diseases is on the physicians' agenda. Considering that albumin is the most abundant plasma protein, designing an appropriate method to purify it is highly important....
متن کاملHigh-performance liquid chromatography of selenoamino acids and organo selenium compounds. Speciation by inductively coupled plasma mass spectrometry.
As part of an ongoing study to identify selenium compounds with cancer chemopreventive activity, extracts of selenium-enriched samples were analyzed by HPLC-inductively coupled plasma (ICP)-MS. Ion-exchange, ion pair and derivatization methods for reversed-phase HPLC were considered and advantages and disadvantages for each compared. Anion exchange allows separation of selenite and selenate, bu...
متن کاملAnalysis of plasma amino acids by HPLC with photodiode array and fluorescence detection.
BACKGROUND Plasma amino acids are usually analyzed by ion-exchange chromatography (IEC), a reproducible but time consuming method. Here, we test whether plasma amino acids can be analyzed using reverse-phase high performance liquid chromatography (HPLC). METHODS Filtered plasma, with S-carboxymethyl-l-cysteine as the internal standard, was derivatized and analyzed by an Agilent 1100 HPLC syst...
متن کاملDevelopment of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol
A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 14 شماره
صفحات -
تاریخ انتشار 1992