Fully automated establishment of stereotaxic image orientation in six degrees of freedom for technetium-99m-ECD brain SPECT.

نویسندگان

  • J Tsao
  • A Stundzia
  • M Ichise
چکیده

UNLABELLED Anatomical localization requires establishing an anatomical space within the image matrix. We developed a fast, fully automated method to establish the image orientation for 99mTc-ethylcysteinate dimer (ECD) brain SPECT images. METHODS The image orientation of ECD brain SPECT images was established in four stages. First, the brain surface was edge-detected as an isosurface at an adaptive threshold. Second, a "convex hull" was determined for the isosurface to minimize regional variability in brain shape. A principal axis transformation and a symmetry vector analysis were applied to the convex hull to resolve the craniocaudal direction and to estimate the midsagittal plane. Third, the brain orientation was refined from this estimate by location of the interhemispheric fissure, the tentorial groove and the frontotemporal groove on the isosurface. Last, the intercommissural (anterior commissure-posterior commissure, or AC-PC) line was detected on the midsagittal slice, and the Talairach grid was scaled to fit the maximal brain dimensions from the AC-PC line. RESULTS The average absolute errors were 2.3 degrees +/- 1.5 degrees and 1.08 mm +/- 1.11 mm for the midsagittal plane (n = 24) and 2.04 degrees +/- 0.80 degrees, 2.0% +/- 1.8% of the brain length and 2.3% +/- 2.2% of the brain height for the AC-PC line (n = 8). In addition, this program successfully established the image orientation in 94 of 100 clinical ECD brain SPECT studies. Processing time was <40 sec for 128 x 128 x 50 matrices on a DEC Alpha workstation. CONCLUSION We have developed a fast, robust and fully automated method that determines the orientation of ECD brain SPECT images. This objective method of standardizing the image orientation should be useful for anatomical localization and clinical interpretation of these images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Database of normal human cerebral blood flow measured by SPECT: I. Comparison between I-123-IMP, Tc-99m-HMPAO, and Tc-99m-ECD as referred with O-15 labeled water PET and voxel-based morphometry.

OBJECTIVES Three accumulative tracers, iodine-123-labeled N-isopropyl-p-iodoamphetamine (I-123-IMP), technetium-99m-labeled hexamethylpropyleneamineoxime (Tc-99m-HMPAO), and technetium-99m-labeled ethyl cysteinate dimer (Tc-99m-ECD) are widely used to measure cerebral blood flow (CBF) in single-photon emission computed tomography (SPECT). In the present study, normal regional distribution of CB...

متن کامل

Atypical finding of brain Tc-99m-ECD SPECT imaging in herpes simplex encephalitis.

Lesions in acute herpes simplex encephalitis (HSE) have been reported to show decreased uptake of Tc-99m ethyl cysteinate dimer (ECD). A patient with acute HSE displaying a lesion in the left temporal lobe was evaluated by means of Tc-99m ECD single-photon emission computed tomography (SPECT). Dynamic SPECT images indicated regionally increased uptake of tracer in the ipsilateral temporal lobe ...

متن کامل

Tc-ECD SPECT Image in Children with Gilles de la Tourette’s Syndrome: A Preliminary Report

Received 4/10/2001; revised 4/25/2001; accepted 5/4/2001. For correspondence or reprints contact: Chia-Hung Kao, M.D., Department of Nuclear Medicine, China Medical College Hospital, 2, Yuh-Der Road, Taichung 404, Taiwan. Tel: (886)4-22052121 ext. 1424/4002, Fax: (886)4-22023442 E-mail: [email protected] Background: Gilles de la Tourette’s syndrome (GTS) is a complex neuropsychiatric disord...

متن کامل

Prognostication of recovery in patients with acute ischemic stroke through the use of brain SPECT with Technetium-99m--labeled metronidazole.

BACKGROUND AND PURPOSE We hypothesized that technetium-99m-ethylene dicysteine-metronidazole (99mTc-EC-MN) localizes to brain tissue that is hypoxic but viable. This study prospectively evaluated the relationship between neurological outcome and uptake of 99mTc-EC-MN in peri-infarcted regions of the brain. METHODS Eight patients with acute ischemic stroke in the territory of the left middle c...

متن کامل

Development of "super rapid dynamic SPECT," and analysis of retention process of 99mTc-ECD in ischemic lesions: comparative study with 133Xe SPECT.

To analyze the retention process of technetium-99m ethyl cysteinate dimer (99mTc-ECD) in normal and ischemic lesions, we developed a super rapid dynamic SPECT system based on the CERASPECT (DSI, Inc., Waltham, MA, USA). The system made it possible to take a SPECT series every 2 seconds. Each SPECT series contains a maximum of 16 slices (6.6 mm slice interval) in a matrix size of 32 x 32. The se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 39 3  شماره 

صفحات  -

تاریخ انتشار 1998