The micro-orifice uniform deposit impactor–droplet freezing technique (MOUDI-DFT) for measuring concentrations of ice nucleating particles as a function of size: improvements and initial validation

نویسندگان

  • R. H. Mason
  • C. Chou
  • C. S. McCluskey
  • E. J. T. Levin
  • C. L. Schiller
  • T. C. J. Hill
  • J. A. Huffman
  • P. J. DeMott
  • A. K. Bertram
چکیده

The micro-orifice uniform deposit impactor– droplet freezing technique (MOUDI-DFT) combines particle collection by inertial impaction (via the MOUDI) and a microscope-based immersion freezing apparatus (the DFT) to measure atmospheric concentrations of ice nucleating particles (INPs) as a function of size and temperature. In the first part of this study we improved upon this recently introduced technique. Using optical microscopy, we investigated the non-uniformity of MOUDI aerosol deposits at spatial resolutions of 1, 0.25 mm, and for some stages when necessary 0.10 mm. The results from these measurements show that at a spatial resolution of 1 mm and less, the concentration of particles along the MOUDI aerosol deposits can vary by an order of magnitude or more. Since the total area of a MOUDI aerosol deposit ranges from 425 to 605 mm and the area analyzed by the DFT is approximately 1.2 mm, this non-uniformity needs to be taken into account when using the MOUDI-DFT to determine atmospheric concentrations of INPs. Measurements of the non-uniformity of the MOUDI aerosol deposits were used to select positions on the deposits that had relatively small variations in particle concentration and to build substrate holders for the different MOUDI stages. These substrate holders improve reproducibility by holding the substrate in the same location for each measurement and ensure that DFT analysis is only performed on substrate regions with relatively small variations in particle concentration. In addition, the deposit non-uniformity was used to determine correction factors that take the non-uniformity into account when determining atmospheric concentrations of INPs. In the second part of this study, the MOUDI-DFT utilizing the new substrate holders was compared to the continuous flow diffusion chamber (CFDC) technique of Colorado State University. The intercomparison was done using INP concentrations found by the two instruments during ambient measurements of continental aerosols. Results from two sampling periods were compared, and the INP concentrations determined by the two techniques agreed within experimental uncertainty. The agreement observed here is commensurate with the level of agreement found in other studies where CFDC results were compared to INP concentrations measured with other methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring Submicron-size Fractionated Particulate Matter on Aluminum Impactor Disks

Submicron-sized airborne particulate matter (PM) is not collected well on regular quartz or glass fiber filter papers. We used a micro-orifice uniform deposit impactor (MOUDI) to fractionate PM into 6 size fractions and deposit it on specially designed high-purity thin aluminum disks. The MOUDI separated PM into fractions 56–100, 100–180, 180–320, 320–560, 560–1000, and 1000–1800 nm. Since the ...

متن کامل

Measuring Submicron-Sized Fractionated Particulate Matter on Aluminum Impactor Disks.

Sub-micron sized airborne particulate matter (PM) is not collected well on regular quartz or glass fiber filter papers. We used a micro-orifice uniform deposit impactor (MOUDI) to fractionate PM into six size fractions and deposit it on specially designed high purity thin aluminum disks. The MOUDI separated PM into fractions 56-100 nm, 100-180 nm, 180-320 nm, 320-560 nm, 560-1000 nm, and 1000-1...

متن کامل

MOUDI analysis of particle size distributions for ultrasonic spraying of salt solutions from an array of microscopic orifices

We report characterization of spray-based nanoporous particle synthesis for use in the cathode of lithiumion batteries. Ultrasonic Microarray Spray Tuning (uMIST) was used to create microdroplets of salt solutions and battery material precursors, and the size distributions of produced microdroplets were investigated with a MicroOrifice Uniform Deposit Impactor (MOUDI). Experimental challenges a...

متن کامل

Use of two different acidic aerosol samplers to measure acidic aerosols in Hsinchu, Taiwan.

Acidic aerosol concentrations measured by an annular denuder system (ADS) and a honeycomb denuder system (HDS) in Hsinchu, Taiwan, were compared. Aerosols were also sampled by a MOUDI (micro-orifice uniform deposit impactor) and analyzed by an ion chromatograph to determine the size distributions of different species. Using the measured aerosol size distribution, theoretical analysis showed tha...

متن کامل

Characteristics of Exposure to Particles due to Incense Burning inside Temples in Kanpur, India

Incense burning in temples is a common and popular ritual in India and other Asian countries. This study aims at assessing the quantity and size segregated distribution of particulate matter in temples of Kanpur city, India. Active air sampling was performed in three temples using the Micro Orifice Uniform Deposit Impactor (MOUDI). PM10 mass concentrations as high as 2184 μg m were recorded ins...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015