The national glycohemoglobin standardization program: a five-year progress report.

نویسندگان

  • R R Little
  • C L Rohlfing
  • H M Wiedmeyer
  • G L Myers
  • D B Sacks
  • D E Goldstein
چکیده

BACKGROUND The Diabetes Control and Complications Trial (DCCT) and the United Kingdom Prospective Diabetes Study (UKPDS) demonstrated conclusively that risks for complications in patients with diabetes are directly related to glycemic control, as measured by glycohemoglobin (GHB). In 1994, one year after the DCCT results were reported, the American Diabetes Association (ADA) set specific diabetes treatment goals. However, 1993 College of American Pathologists (CAP) Survey results indicated a lack of comparability of GHB test results among methods and laboratories that represented a major obstacle to meaningful implementation of the ADA guidelines. Thus, an AACC subcommittee was formed in 1993 to develop a standardization program that would enable laboratories to report DCCT-traceable GHB results. This program was implemented in 1996 by the National Glycohemoglobin Standardization Program (NGSP) Steering Committee. APPROACH We review the NGSP process and summarize progress in standardization through analysis of CAP data. CONTENT Since 1996, the number of methods and laboratories certified by the NGSP as traceable to the DCCT has steadily increased. CAP GH2-B survey results reported in December 2000 show marked improvement over 1993 data in the comparability of GHB results. In 2000, 90% of surveyed laboratories reported GHB results as hemoglobin A(1c) (HbA(1c)) or equivalent, compared with 50% in 1993. Of laboratories reporting HbA(1c) in 2000, 78% used a NGSP-certified method. For most certified methods in 2000, between-laboratory CVs were <5%. For all certified methods in 2000, the mean percent HbA(1c) was within 0.8% HbA(1c) of the NGSP target at all HbA(1c) concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

S-Nitrosothiols in blood: does photosensitivity explain a 4-order-of-magnitude concentration range?

1. Little RR, Rohlfing CL, Wiedmeyer HM, Myers GL, Sacks DB, Goldstein DE. The national glycohemoglobin standardization program: a five-year progress report. Clin Chem 2001;47: 1985–92. 2. Rohlfing CL, Wiedmeyer HM, Little RR, England JD, Tennill A, Goldstein DE. Defining the relationship between plasma glucose and HbA1c: analysis of glucose profiles and HbA1c in the Diabetes Control and Compli...

متن کامل

Influence of variables on hemoglobin A1c values and nonheterogeneity of hemoglobin A1c reference ranges.

INTRODUCTION Hemoglobin A1c (HbA1c) values are influenced by analytical interferences such as HbF and hemoglobin variants and clinical factors such as increased red cell turnover. Although less well-known, demographic factors such as race, age, and sex also influence HbA1c values. The HbA1c reference range should be homogenous in the United States based on the use of National Glycohemoglobin St...

متن کامل

Issues in immunoassay standardization: the ARCHITECT Folate model for intermethod harmonization.

Extensive variability among folate assay methods has been well described. A FLAIR round-robin study of serum and whole-blood folate results across 11 laboratories in seven European countries reported overall CVs of 18–41% (1 ). A CDC round-robin survey of 20 laboratories reported twoto ninefold differences in folate values among methods and laboratories (2 ). With increasing awareness of the nu...

متن کامل

Wiskott-Aldrich Syndrome (WAS): A Case Report in Mauritius and Review

Wiskott-Aldrich is an X-lined recessive disorder typically characterized by thrombocytopenia, eczema and recurrent infections. We report the four year treatment progress of a six year old boy who initially presented with vesicular lesions over the trunk, upper and lower extremities and face and blood tinged stools at the age of 2 weeks. From the family pedigree, there were two suspected cases t...

متن کامل

Causes of Low HbA1c in Malaysian University Hospital.

INTRODUCTION Glycohemoglobin (HbA1c) most accurately reflects the previous two to three months of glycaemic control. HbA1c should be measured regularly in all patients with diabetes, and values should be maintained below 7% to prevent the risk of chronic complications. Apart from the genetic variants of haemoglobins many other conditions also known to affect HbA1c measurements. In this study we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 11  شماره 

صفحات  -

تاریخ انتشار 2001