Pii: S1010-7940(01)01064-8

نویسندگان

  • Theo Kofidis
  • Stefan Fischer
  • Rainer Leyh
  • Helmut Mair
  • Maria Deckert
  • Roman Haberl
  • Axel Haverich
  • Bruno Reichart
چکیده

Objectives: There has been frequent report on transcranially detected microembolic signals (HITS) following cardiac surgery using extracorporeal bypass support. The clinical relevance of HITS, however, has yet to be clarified. The incidence of thromboembolic events is increased following mechanical heart valve replacement. The purpose of this study was to quantify postoperative HITS after implantation of two types of prosthetic aortic valves and to compare both types of mechanical valves with respect to the generation of HITS. In addition, HITS rates were correlated with clinical, echocardiographical and laboratory findings. Methods: Forty-two patients following implantation of either a Sorin Biomedica heart valve (n 1⁄4 22, group A) or a Tekna Duromedics mechanical valve (n 1⁄4 20, group B) were examined. A group of ten healthy volunteers served as control. Clinical, echocardiographic, carotid artery duplex and laboratory examinations were performed in all patients. A 60 min bilateral transcranial doppler monitoring of the medial cerebral artery (MCA) was also carried out in order to evaluate cerebral blood flow. Results: In group A 14 of 22 patients were positive for HITS (53%), with an average of 16.4 ^ 19 HITS/pt.h. In group B 15 of 20 patients were HITS positive (75%) with an average amount of 14.4 ^ 24 HITS/pt.h. The incidence of HITS was not significantly different between the two groups. No correlation was seen between the HITS-rate/h and neurological findings, duplex sonographic results, mechanical valve size and anticoagulation regimen (P . 0:05). However, a negative correlation was observed between patient age and HITS-rate (P 1⁄4 0:02) as well as between the NYHA degree and HITS-rate (P 1⁄4 0:018). The HITS-rate also correlated with postoperative time (P 1⁄4 0:042). No HITS were detected in the control group. Conclusions: HITS do not correlate with the individual clinical status and, thus, cannot predict the occurrence of neurological deficits in patients following mechanical aortic valve implantation. q 2002 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S1010-7940(01)01137-x

We report the laparoscopic transhiatal thoracic duct ligation to solve postoperative chylothorax after right total pleurectomy for malignant diffuse mesothelioma. q 2002 Elsevier Science B.V. All rights reserved.

متن کامل

Pii: S1010-7940(01)00715-1

Constrictive pericarditis is a relatively rare clinical manifestation nowadays. We present the case of an HIV-positive patient with constrictive calci®ed pericarditis due to an infection with Mycobacterium tuberculosis. Pericardectomie was performed. The therapeutical approach is discussed and the literature is reviewed. q 2001 Elsevier Science B.V. All rights reserved.

متن کامل

Pii: S1010-7940(01)01094-6

Endocarditis involving the central fibrous body of the heart requires carefully planned surgical intervention. We present a novel approach in a 65-year-old male with extensive endocarditis involving the aortic root, ventricular septum, central fibrous body together with mitral, aortic and tricuspid valves. q 2002 Elsevier Science B.V. All rights reserved.

متن کامل

Pii: S1010-7940(01)01160-5

The Jarvik-2000 is an axial-flow left-ventricular-assist-device (LVAD) designed for permanent use. The power supply is provided by a cable plugged into a skull-pedestal mounted in the retro-auricular area. We describe the surgical technique and discuss potential and encountered problems. q 2002 Elsevier Science B.V. All rights reserved.

متن کامل

Pii: S1010-7940(01)00993-9

The length of the in situ right internal mammary artery (RIMA) often restricts its use as a graft to distal marginal arteries. We describe herein a retrocaval supra-azygous extra-pleural passage of the RIMA that allows a significant gain in length. We report our experience in 30 patients with distal marginal lesions or with large hearts. q 2001 Elsevier Science B.V. All rights reserved.

متن کامل

Pii: S1010-7940(01)00916-2

We present here a case of end-stage non-ischemic valvular dilated cardiomyopathy (DCM) associated with mitral regurgitation (MR). The patient underwent surgery where left ventricular volume reduction using endoventricular circular patch plasty (EVCPP) and mitral valve replacement (MVR) were performed. He has improved much after the operation and is now in New York Heart Association (NYHA) funct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001